Frage 1

Frage
What would be the fire resistance requirement of a mechanical shaft connecting the 5 stories of a new office building?
Antworten
  • 3-hour fire-resistance
  • 2-hour fire-resistance
  • 1-hour fire-resistance
  • None of the above

Frage 2

Frage
According to the 2018 IBC, what is the minimum number of intermediate landings of an egress stair, necessary to connect 2 floors with an elevation difference of 25′-0″?
Antworten
  • 1
  • 2
  • 3
  • 4

Frage 3

Frage
Which of the following are examples of organizations that develop standards? Check all that apply.
Antworten
  • American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
  • The National Fire Protection Association (NFPA)
  • American Iron and Steel Institute (AISI)
  • The American National Standards Institute (ANSI)
  • ASTM International

Frage 4

Frage
According to the 2018 IBC, which of the following is a Class B material?
Antworten
  • Flame spread index - 23 Smoke-developed index - 350
  • Flame spread index - 27 Smoke-developed index - 50
  • Flame spread index - 81 Smoke-developed index - 400
  • Flame spread index - 95 Smoke-developed index - 25

Frage 5

Frage
Which of the following changes in level are not ADA compliant? Check the two that apply.
Antworten
  • 1/4 " vertical change
  • 1/2 " change with a 1:2 bevel
  • 1/3 " change with a 1:2 bevel
  • 1/3" vertical change
  • 1/2 " change with a 3:4 bevel
  • 1/4 " change with a 1:4 bevel

Frage 6

Frage
Which of the following materials would have the highest FSI after being submitted to ASTM E84 testing?
Antworten
  • Brick
  • Gypsum Wallboard
  • Gypsum Sheathing
  • White Oak

Frage 7

Frage
Per the 2010 ADA Standards, what are the minimum maneuvering clearances missing in the image below?
Antworten
  • 50" and 24"
  • 48" and 24"
  • 42" and 22"
  • 48" and 18"

Frage 8

Frage
How would an accessory occupancy typically be separated from the main occupancy?
Antworten
  • No separation is required
  • 1-Hour fire barrier
  • 2-Hour fire barrier
  • 1-Hour fire barrier or sprinkler system

Frage 9

Frage
Based on the table below, how many accessible parking stalls are required on a 466,900-sf parking lot? Assume an overall efficiency of 350 sf per parking space.
Antworten
  • 20
  • 24
  • 28
  • 32

Frage 10

Frage
Which of the following sentences are correct? Check all that apply.
Antworten
  • Doors in any position shall not reduce the required egress width by more than one-half
  • Doors, when fully opened, shall not reduce the required egress width by more than 7"
  • Doors in any position shall not reduce the required egress width by more than one-third
  • Doors, when fully opened, shall not reduce the required egress width by more than 4"
  • Wall mounted fixtures, at a height of 70", shall not project horizontally from either side more than 4"
  • Wall mounted fixtures, at a height of 70", shall not project horizontally from either side more than 7"
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

PDD Quiz XII
a a
PDD Quiz I
a a
Step 3 - Probetest
Niklas Coco
03_Offene Handelsgesellschaft
Stefan Kurtenbach
Kraftwerke und Stromsicherheit
Peter Kasebacher
Deutsche Redewendungen und Umgangssprache / Quiz 03
deutschlernerblog.de
Oxford Academic Word List Sub1
torsten fab
Grundzüge Soziologie Richter
Kamila rURKA
Vetie - Histo & Embryo - P 2017
Fioras Hu
Vetie - Berufsrecht 2016
Kim Langner