MRI Parameters and Trade-offs
Description
Quiz on MRI Parameters and Trade-offs, created by meganpm on 04/04/2015.
No tags specified
mri
Quiz by
meganpm
, updated more than 1 year ago
More
Less
Created by
meganpm
over 9 years ago
328
0
0
Resource summary
Question 1
Question
The scan time for a 3D acquisition is given by:
Answer
TR X NEX X phase encodings X number of slices
TR X NEX X phase encodings X slice thickness
(TR X NEX X phase encodings)/echo train length
TR X NEX X phase encodings
Question 2
Question
The scan time for a 2D acquisition is determined by:
Answer
TR X NEX X phase encodings X FOV
TR X NEX X phase encodings X number of slices
TR X NEX X phase encodings X slice thickness
TR X NEX X phase encodings
Question 3
Question
During a conventional spin echo exam, one line of k-space is filled each
Answer
frequency encoding period
TE period
TR period
TI period
Question 4
Question
Noise represents
Answer
current induced in the phase encoding gradient
frequencies that exist randomly in space and time
frequencies that exist in a structured environment at a specific location
Un-captured voltage potential
Question 5
Question
Changing the size of a voxel in the frequency direction will
Answer
have no effect on the scan time
double the scan time
increase the scan time by a factor of 0.5
Question 6
Question
What is the slice thickness for an isotropic voxel with a 20 cm field of view and a 256 X 256 matrix
Answer
13 cm
0.8 mm
3 cm
1.3 mm
Question 7
Question
Where in a spin echo pulse sequence are pre-saturation pulses usually placed?
Answer
after the excitation pulse
after the 180 degree RF pulse
between the 90 degree and 180 degree RF pulse
prior to the excitation pulse
Question 8
Question
Which of the following TR parameters will provide the highest signal to noise?
Answer
1800 ms
400 ms
2500 ms
800 ms
Question 9
Question
Which of the following TE parameters will provide the highest signal to noise?
Answer
120 ms
20 ms
40 ms
80 ms
Question 10
Question
Which of the following flip angles will provide the highest signal to noise?
Answer
45 degrees
115 degrees
90 degrees
5 degrees
Show full summary
Hide full summary
Want to create your own
Quizzes
for
free
with GoConqr?
Learn more
.
Similar
x-sectional anatomy
Korie Hi
MRI Scans
Heloise Tudor
Imaging in Gynaecology
Matthew Coulson
Medical Physics
Tim Davidson
Diagnostic Imaging Technology
Tashelle Davis
Diagnostic Imaging Technology
Keyria M
Michael Colombini - MRI Case_1
Nikki Davidson
Case 1
Poh Sun Goh
Pythagorean Theorem Quiz
Selam H
B5 - Growth and Deveolopment
blairzy123
GCSE AQA Biology - Unit 3
James Jolliffe
Browse Library