MRI Parameters and Trade-offs

Descripción

Test sobre MRI Parameters and Trade-offs, creado por meganpm el 04/04/2015.
meganpm
Test por meganpm, actualizado hace más de 1 año
meganpm
Creado por meganpm hace más de 9 años
317
0

Resumen del Recurso

Pregunta 1

Pregunta
The scan time for a 3D acquisition is given by:
Respuesta
  • TR X NEX X phase encodings X number of slices
  • TR X NEX X phase encodings X slice thickness
  • (TR X NEX X phase encodings)/echo train length
  • TR X NEX X phase encodings

Pregunta 2

Pregunta
The scan time for a 2D acquisition is determined by:
Respuesta
  • TR X NEX X phase encodings X FOV
  • TR X NEX X phase encodings X number of slices
  • TR X NEX X phase encodings X slice thickness
  • TR X NEX X phase encodings

Pregunta 3

Pregunta
During a conventional spin echo exam, one line of k-space is filled each
Respuesta
  • frequency encoding period
  • TE period
  • TR period
  • TI period

Pregunta 4

Pregunta
Noise represents
Respuesta
  • current induced in the phase encoding gradient
  • frequencies that exist randomly in space and time
  • frequencies that exist in a structured environment at a specific location
  • Un-captured voltage potential

Pregunta 5

Pregunta
Changing the size of a voxel in the frequency direction will
Respuesta
  • have no effect on the scan time
  • double the scan time
  • increase the scan time by a factor of 0.5

Pregunta 6

Pregunta
What is the slice thickness for an isotropic voxel with a 20 cm field of view and a 256 X 256 matrix
Respuesta
  • 13 cm
  • 0.8 mm
  • 3 cm
  • 1.3 mm

Pregunta 7

Pregunta
Where in a spin echo pulse sequence are pre-saturation pulses usually placed?
Respuesta
  • after the excitation pulse
  • after the 180 degree RF pulse
  • between the 90 degree and 180 degree RF pulse
  • prior to the excitation pulse

Pregunta 8

Pregunta
Which of the following TR parameters will provide the highest signal to noise?
Respuesta
  • 1800 ms
  • 400 ms
  • 2500 ms
  • 800 ms

Pregunta 9

Pregunta
Which of the following TE parameters will provide the highest signal to noise?
Respuesta
  • 120 ms
  • 20 ms
  • 40 ms
  • 80 ms

Pregunta 10

Pregunta
Which of the following flip angles will provide the highest signal to noise?
Respuesta
  • 45 degrees
  • 115 degrees
  • 90 degrees
  • 5 degrees
Mostrar resumen completo Ocultar resumen completo

Similar

x-sectional anatomy
Korie Hi
MRI Scans
Heloise Tudor
Imaging in Gynaecology
Matthew Coulson
Medical Physics
Tim Davidson
Diagnostic Imaging Technology
Tashelle Davis
Diagnostic Imaging Technology
Keyria M
Michael Colombini - MRI Case_1
Nikki Davidson
Case 1
Poh Sun Goh
antonimos I
Kioshi Gonzales
Leyes de Mendel
crisferroeldeluna
PRINCIPIO DE OPORTUNIDAD DEL MINISTERIO PÚBLICO ART. 256
ConsentidadeDios