Unit 203 Revision Question Bank No.2

Descripción

C&G 2365 Level 2 Unit 203 Revision (Bank 2) OB
Oliver Balay
Test por Oliver Balay, actualizado hace más de 1 año
Oliver Balay
Creado por Oliver Balay hace más de 9 años
9780
7

Resumen del Recurso

Pregunta 1

Pregunta
If a steel wire armoured cable had an overall diameter of 16mm what would be the maximum spacing of clips on a horizontal run
Respuesta
  • 250mm
  • 450mm
  • 400mm
  • 0.5m

Pregunta 2

Pregunta
If Band 1 and Band 2 circuits are run through the same trunking what special requirements must you achieve?
Respuesta
  • Cables to be run in the opposite direction
  • Cables are installed in separate compartments
  • Are not permitted in Trunking
  • Must be able to carry the same colour Live and Neutral conductors

Pregunta 3

Pregunta
If the ambient temperature increases the copper cable will
Respuesta
  • Increase resistance
  • Decrease resistance
  • Stay the same
  • Will melt

Pregunta 4

Pregunta
If the distance of an interactive whiteboard is 2m and the measurement taken is 4cm what is the scale of the drawing
Respuesta
  • 1:20
  • 1:100
  • 1:40
  • 1:50

Pregunta 5

Pregunta
If the distance of a wall is 4m and the measurement taken by the drawing is 4cm what is the scale
Respuesta
  • 1:75
  • 1:100
  • 1:50
  • 1:20

Pregunta 6

Pregunta
In a switch started fluorescent tube circuit, the function of the choke when the lamp is lit, is to
Respuesta
  • Limit current flowing in the lamp
  • Produce a voltage surge across the lamp
  • Cause current in the circuit to leap voltage.
  • Increase current flow in the circuit

Pregunta 7

Pregunta
In electrical systems, the definition of isolation is:
Respuesta
  • Placing conductors from each circuit in separate conduit
  • Protecting each circuit by a separate circuit breaker
  • Cutting off electrical energy from every power source
  • Isolating circuits & equipment from the general mass of earth

Pregunta 8

Pregunta
In order to determine types of materials and quantities required to complete an electrical installation, an estimator will require:
Respuesta
  • Operating sheets & manufacturers' models
  • Exploded view diagrams & data sheets
  • A technical drawing & data sheet
  • Specification & wiring diagram

Pregunta 9

Pregunta
For large number of computers installed on a large [LAN] network, what cable would you use?
Respuesta
  • Steel wired armour
  • Fibre optics
  • PVC
  • MICC

Pregunta 10

Pregunta
On a construction site the voltage to be used for power tools is restricted to
Respuesta
  • 110V AC
  • 230V AC
  • 110V DC
  • 55V AC

Pregunta 11

Pregunta
On site, where a crane is operating overhead, in addition to a safety helmet an electrician should wear
Respuesta
  • Face mask
  • A high visibility jacket
  • Rubber soled shoes
  • A donkey jacket

Pregunta 12

Pregunta
Operating characteristics information supplied with electric motors by the manufacturers is in the form of:
Respuesta
  • Data sheets
  • Memoranda
  • Circuit diagrams
  • Wiring diagrams

Pregunta 13

Pregunta
Overload can occur in a circuit if
Respuesta
  • A short circuit is present between line and neutral
  • The circuit is electrically sound
  • Between two conductors at different potentials
  • If there is a loose connection of conductors

Pregunta 14

Pregunta
PVC & metal conduit are fixed using:
Respuesta
  • Crampets
  • Spiral fixings
  • Cleats
  • Saddles

Pregunta 15

Pregunta
Solar Thermal installations work on which principle
Respuesta
  • Water passes through the panel allowing the generator to rotate.
  • Wind hits the panels and creates an electro motive force through the semiconductor material
  • Sun hits the panels and warms up the water.
  • Sun hits the panels and turn into electricity

Pregunta 16

Pregunta
The British Standard for a cartridge fuse used in 13A plug tops
Respuesta
  • BS 88
  • BS 1361
  • BS 1362
  • BS 3036

Pregunta 17

Pregunta
The cables that connect between two 2 way switches are said to be called
Respuesta
  • Switch wires
  • Strippers
  • Switch lines
  • Strappers

Pregunta 18

Pregunta
The distribution supply cable to a building is usually:
Respuesta
  • Steel Wire Armoured
  • PVC sheathed & insulated
  • PVC insulated in steel conduit
  • Mineral Insulated

Pregunta 19

Pregunta
The earthing arrangement when incoming supply cable sheath provides an independent earth is
Respuesta
  • TN - C
  • TT
  • TN - S
  • TN - C - S

Pregunta 20

Pregunta
The main reason to fix cable to walls on horizontal runs using appropriate clips at suitable intervals is to prevent:
Respuesta
  • Untidy appearance
  • Stress on the cable
  • Stop the cable being pulled down
  • Stray magnetic fields

Pregunta 21

Pregunta
The maximum disconnection time for a circuit over 32A is
Respuesta
  • 1 second
  • 0.4 seconds
  • 0.2 seconds
  • 5 seconds

Pregunta 22

Pregunta
The maximum number of accidents on a construction site is due to
Respuesta
  • Falling/tripping/manual handling
  • Falling/manual handling/use of equipment
  • Tripping/manul handling/use of equipment
  • Use of materials/falling/manual handling

Pregunta 23

Pregunta
The maximum span between buildings for unjointed 25mm diameter steel conduit is
Respuesta
  • 2m
  • 3m
  • 2.5m
  • 1.5 m

Pregunta 24

Pregunta
The most accurate method of forming right angle bends in steel conduit is:
Respuesta
  • A vice and heat source
  • A wooden block
  • The knee
  • A bending machine

Pregunta 25

Pregunta
The most important factor when selecting a cable of known rating is:
Respuesta
  • Colour of insulation
  • The temperature of operation
  • Shape of the outer sheath
  • Distance between cable cores

Pregunta 26

Pregunta
The purpose of the day work sheet is to record
Respuesta
  • All worked hours
  • Hours worked in addition to the main contract
  • All work to be carried out in one day
  • Any work related expenses to be claimed from petty cash

Pregunta 27

Pregunta
The purpose of the pvc sheath on a pvc/pvc multicore cable is to
Respuesta
  • Prevent damage to insulation
  • Provide a CPC
  • Provide a fixing point for plug cord grips
  • Colour code the cable

Pregunta 28

Pregunta
The rating of an RCD installed to provide additional protection for equipment used outside the main equipotential zone is?
Respuesta
  • 30mA
  • 500mA
  • 100mA
  • 50mA

Pregunta 29

Pregunta
The standard transmission high voltage is
Respuesta
  • 11kV
  • 400V
  • 11kV
  • 400kV

Pregunta 30

Pregunta
The stop button used to allow isolation of electrical equipment for maintenance must:
Respuesta
  • Easy to re-close
  • Placed close to the incoming supply
  • Able to be bypassed
  • Be impossible to re-close unintentionally

Pregunta 31

Pregunta
The symbol Ca is used to represent which rating factor
Respuesta
  • Thermal Insulation
  • Installation Condition
  • Ambient temperature
  • Grouping

Pregunta 32

Pregunta
To mark out metal trunking for cutting, you would use:
Respuesta
  • Rule, square & scriber
  • Gauge, level & tape
  • Knife, hammer & screwdriver
  • Vee block, saw & chisel

Pregunta 33

Pregunta
Vertical & horizontal runs of trunking must be adequately supported to:
Respuesta
  • Provide earth continuity
  • Avoid stress & damage to the cable
  • Prevent possible fire damage
  • Prevent distortion to the trunking

Pregunta 34

Pregunta
Which cable type is most suitable for cable cleats?
Respuesta
  • Singles
  • Steel wire armoured
  • MICC
  • PVC/PVC/CPC

Pregunta 35

Pregunta
What conductor is used to connect to extraneous conductive parts?
Respuesta
  • Main Protective Bonding conductor
  • Main Earthing conductor
  • Circuit Protective conductor
  • Earth Sleeving

Pregunta 36

Pregunta
What does the following picture show?
Respuesta
  • Spacer Bar Saddle
  • Cable Cleat
  • Hospital Saddle
  • Crampet

Pregunta 37

Pregunta
What fixings would be used on a hollow partition wall?
Respuesta
  • Rawl plug
  • Spring toggle
  • Screw
  • Cable cleat

Pregunta 38

Pregunta
What fixings would be used on a brick wall?
Respuesta
  • Rawl plug and round headed wood screw
  • Spring toggle
  • Self-adhesive tape
  • Gravity toggle

Pregunta 39

Pregunta
What form of switching is used on a security system?
Respuesta
  • Relay
  • Contactor
  • Direct on line starter
  • One way switch

Pregunta 40

Pregunta
What is the conduit factor for a 4m 20mm conduit which incorporates two bends?
Respuesta
  • 222
  • 204
  • 91
  • 213
Mostrar resumen completo Ocultar resumen completo

Similar

WJEC Level 2 Latin Language Vocabulary (A)
Gian Hernandez
WJEC Level 2 Latin Language Vocabulary (T)
Gian Hernandez
Unit 203 Revision: Installation Technology Question Bank No.1
Oliver Balay
WJEC Level 2 Latin Language Vocabulary (E&F)
Gian Hernandez
Unit 203 Revision: Installation Technology Question Bank No.1
Jamie Parslow-Williams
WJEC Level 2 Latin Language Vocabulary (S)
Gian Hernandez
Unit 203 Revision: Installation Technology Question Bank No.1
james seaman
Unit 203 Revision: Installation Technology Question Bank No.1
dave love
WJEC Level 2 Latin Language Vocabulary (M)
Gian Hernandez
WJEC Level 2 Latin Language Vocabulary (N)
Gian Hernandez
WJEC Level 2 Latin Language Vocabulary (I)
Gian Hernandez