Water supply and hydraulics Part 1

Descrição

FlashCards sobre Water supply and hydraulics Part 1, criado por Jake U em 20-09-2015.
Jake U
FlashCards por Jake U, atualizado more than 1 year ago
Jake U
Criado por Jake U aproximadamente 9 anos atrás
22
0

Resumo de Recurso

Questão Responda
Specific heat Ratio between amount of heat needed to raise the temp of a specified quantity of material and the amount of heat needed to raise the temp of an identical quantity of water by the same number of degrees. Water has a specific heat of 1:1
Latent heat of vaporization Amount of heat absorbed by any substance when it is converted from a liquid to a vapor. Water vaporizes at 100 degrees
Water expands ____ when converted to steam 1700 times
Disadvantages of water (6 points) - high surface tension - low opacity - low viscosity - conducts electricity - reacts with certain chemicals - steam can cause injury
Dead end hydrant Receives water from only one direction
Circulating loop hydrant When water feeds into the hydrant from 2 or more directions. Allows for higher pressure
How many fire hydrants are in Edmonton 18,000 +
Which way do hydrants open Counter clockwise
Static Pressure Pressure of water when it is not moving
Normal operating pressure Pressures within distribution system during normal consumption demands
Residual Pressure Total available pressure not used to overcome friction or gravity when water is flowing throughout system
Flow Pressure Forward velocity pressure at any discharge opening
Water hammer the destructive forces which develop in a piping system when a column of noncompressible liquid is stopped abruptly. **The pressure exerted can be 7X or more than the static pressure.
What is the LPM for a Blue/Black/Silver capped hydrant Greater than 5700 LPM
Green capped 3800-5700 LPM
Yellow orange capped 1900-3800 LPM
Red capped Less than 1900 LPM
Orange service ring Out of service
Green service ring Dont use, under construction
Blue service ring in use (permitted)
white service ring FD use only
On board water capacity of Pumper 1890 litres
On board water capacity of Ladder 1134 L
On board water capacity of tankers 4500 L
On board water capacity of Supertankers 13,500 L
On board water capacity of ATP 1142 L
On board water capacity of Mule trailer 250 L
44mm attack hose nozzle pressure, rated flow, and FL NP=500kpa Flow=550lpm FL=100kpa per 15m length
65mm hose nozzle pressure, rated flow, and FL NP=500kpa Flow=950lpm FL=50kpa per length
What size is the jumpline and how long is it 44mm - limited to 30m
How many lengths of 125mm hi vol are on each apparatus Pump = 20 lengths Tanker = 15 Ladder = 9 Quint = 4
150mm suction hose on the pumps and tankers comes in ___m lengths 4 or 5 meter. It is used for drafting.
What size of hose are found on each apparatus Pump - all hose except for booster Ladder - 44mm,65mm,125mm Tanker and supertanker - everything ATP - Booster, 38mm, 65mm
What 4 kinds of hose damage are there Mechanical, Thermal, Organic, Chemical
What are the hose testing pressures for the 44mm, 65mm, and 125mm? How long are the tests? 44mm and 65mm - 1750kpa 125mm - 1400kpa Duration of 3 minutes
How do you start a flat load? By placing one coupling in the front corner of the hose bed
What is a dutchman Reverse bend to change direction or location of a coupling. used to avoid having the coupling flip as hose is deployed.

Semelhante

Big Gate
Jake U
Rank Structure Policies
Jake U
Water supply and hydraulics part 2