Questão 1
Questão
A heating circuit in which the flow and return pipes are completely separated until they connect to the boiler is known as a
Responda
-
a) one pipe system
-
b) two pipe system
-
c) sealed system
-
d) gravity system.
Questão 2
Questão
A British Standard that includes detail on the requirements for installing open vented central heating systems in dwellings is
Responda
-
a) BS EN 12056
-
b) BS 6700
-
c) BS EN 12828
-
d) BS 5449.
Questão 3
Questão
Which pipe connects to port X in the diagram of an air separator below?
Questão 4
Questão
What is the recommended actual capacity of the feed and expansion cistern
in a small open vented indirect central heating system?
Responda
-
a) 6 litres
-
b) 18 litres
-
c) 52 litres
-
d) 100 litres.
Questão 5
Questão
What is the name of the component shown below?
Responda
-
a) Temperature relief valve.
-
b) Pressure relief valve.
-
c) Pressure regulating valve.
-
d) Thermostatic radiator valve.
Questão 6
Questão
Which one of the following gas boilers overcomes the need for a cold water
storage cistern, feed and expansion cistern and hot water storage vessel?
Responda
-
a) Back-boiler.
-
b) Traditional.
-
c) Combination.
-
d) Room-heater.
Questão 7
Questão
What is the recommended maximum clip spacing distance for a vertical 15 mm copper pipe?
Responda
-
a) 1200 mm.
-
b) 1800 mm.
-
c) 2000 mm.
-
d) 2500 mm.
Questão 8
Questão
The Domestic Heating Compliance Guide supports which document?
Responda
-
a) British Standard 8000.
-
b) The Water Supply (Water Fittings) Regulations.
-
c) British Standard 5449.
-
d) Building Regulations Approved Document L1.
Questão 9
Questão
Minimum controls which must be provided when replacing a gravity fed cylinder supplied from a gas boiler, as laid down in the Domestic Heating Compliance Guide, is
Responda
-
a) a thermo-mechanical thermostat
-
b) no minimum control required
-
c) fully motorised two port valve
-
d) electronic thermostat.
Questão 10
Questão
What type of heat emitter is shown in the following photograph?
Responda
-
a)Hospital radiator.
-
b) Panel radiator.
-
c) Column radiator.
-
d) Skirting heater.
Questão 11
Questão
The drawing below shows the connection arrangements to a feed and expansion cistern, pump, open vent and cold feed pipe. What is the likely outcome of positioning the system in the left shown?
Responda
-
a) The cold feed pipe is at the point of highest positive pressure.
-
b) The system will be largely under negative pressure.
-
c) A neutral pressure will be maintained in all system pipework.
-
d) The system will pump over the open vent pipe.
Questão 12
Questão
The minimum size of the cold feed pipe to a fully pumped heating system in a domestic dwelling is
Responda
-
a) 15 mm
-
b) 22 mm
-
c) 28 mm
-
d) 35 mm.
Questão 13
Questão
A three-port mid-position valve can provide heated water to
Responda
-
a) only the heating circuit
-
b) only the hot water circuit
-
c) both the heating and hot water circuit, but not both together
-
d) both the heating or hot water circuit and both together.
Questão 14
Questão
What type of central heating control component is normally used in conjunction with a frost thermostat to conserve energy when exposed parts of a central heating system are required to be protected against frost damage?
Questão 15
Questão
Water in a wet central heating system is normally treated with
Responda
-
a) sodium hypochlorite
-
b) corrosion inhibitor
-
c) caustic soda solution
-
d) disinfectant.
Questão 16
Questão
What type of central heating component is shown in the photograph below?
Responda
-
a) Programmer.
-
b) Timer.
-
c) Motorised valve.
-
d) Room thermostat.
Questão 17
Questão
The method by which panel radiators transmit most of their heat is
Responda
-
a) conduction
-
b) convection
-
c) radiation
-
d) condensation.
Questão 18
Questão
The water level in the feed and expansion cistern of a central heating system should be set to allow sufficient room for
Responda
-
a) thermal expansion of the water
-
b) coping with pumping over
-
c) air venting
-
d) reduction of noise when filling.
Questão 19
Questão
The normal position for a cylinder thermostat that is strapped to a cylinder is approximately
Responda
-
a) at the top of the cylinder
-
b) a third of the way down the cylinder from the top
-
c) half way down the cylinder
-
d) a third of the way up from the bottom of the cylinder.
Questão 20
Questão
The type of heating system that uses 2 x two port motorised valves is known as a
Responda
-
a) A thermostatic radiator valve.
-
b) A lockshield type valve.
-
c) A wheelhead type valve.
-
d) An electro mechanical valve.
Questão 21
Questão
Which component is used in a heating system fitted with a low water content boiler to ensure that a minimum water flow rate is maintained through the boiler heat exchanger at all times?
Responda
-
a) Automatic bypass valve.
-
b) Pressure relief valve.
-
c) Pressure reducing valve.
-
d) Lockshield gate valve.
Questão 22
Questão
A central heating control component which can regulate the on/off periods of two or more zones in a system is known as a
Responda
-
frost thermostat
-
room thermostat
-
thermo-mechanical valve
-
programmer.
Questão 23
Questão
Before you carry out a hydraulic pressure test on a new central heating system you should perform
Responda
-
a) a full disinfection of the system
-
b) a hot flush of the system and add corrosion inhibitor
-
c) a visual inspection of the system
-
d) a heat loss calculation of the system.
Questão 24
Questão
The following diagram shows the actions of which component in a heating system?
Responda
-
a) Boiler fan.
-
b) Circulating pump.
-
c) Shower pump.
-
d) Diverter valve.