Gas practice appliances

Descrição

English Quiz sobre Gas practice appliances , criado por randy loye em 02-06-2018.
randy loye
Quiz por randy loye, atualizado more than 1 year ago
randy loye
Criado por randy loye mais de 6 anos atrás
64
1

Resumo de Recurso

Questão 1

Questão
What are two inert gasses
Responda
  • Carbon monoxide and Aldehydes
  • CO2 and Hydrogen
  • Carbon Monoxide and Nitrogen
  • Carbon Dioxide and Nitrogen

Questão 2

Questão
What are two products of incomplete combustion
Responda
  • Carbon dioxide and Nitrogen
  • Hydrogen and carbon
  • Carbon monoxide and Aldehydes
  • Nitrogen and Aldehydes

Questão 3

Questão
In an induced draft burner the fan is
Responda
  • upstream
  • downstream
  • forced draft burner
  • fans are up and down stream

Questão 4

Questão
In a forced draft burner the fan is
Responda
  • downstream
  • upstream
  • balanced both down and up stream
  • in the combustion chamber

Questão 5

Questão
In a balanced draft burner the fan is
Responda
  • downstream
  • both up and downstream
  • upstream
  • is beside the damper

Questão 6

Questão
A bi-metal strip is
Responda
  • two strips of separate metal that have the same temperature when heated causes them to curve and is used to control and open an electrical circuit
  • is two strips of metal welded together with different coefficients temperatures when heated causes them to curve and is used to control and open an electrical circuit
  • two pieces of metal use for thermostat sensing

Questão 7

Questão
A thermistor is
Responda
  • a thermostat
  • a rod and tube device used in water heaters
  • a device used to measure room temperature and regulate electrical flow to equipment control's circuit
  • used to measure the overheating of an appliance

Questão 8

Questão
A capillary is
Responda
  • a device used to measure flow rate of appliance
  • a spring loaded device used operate electrical switches to open or close gas ports. it has a glass bulb at the end that reacts to preasure
  • a device that operates like a pressure relief vale for water
  • a device heat value in gas appliances through a glass tube at the end of the device

Questão 9

Questão
A rod and tube
Responda
  • is two different metals used in hot water tanks to measure pressure and temperature
  • is used as a circuit when the temperate rises it activates an electrical circuit
  • is a device used as a gas line in some cases
  • is two different metals places inside one another which is used as a thermostat and when heated activates a electrical switch or gas valve port

Questão 10

Questão
A thermocouple
Responda
  • is a device used in conjunction with thermostat to measure heat
  • is used in combustion systems to send moisture information and flue gas reading back to main control board
  • is used as a safety device as it measures flames in constant pilot and manual reset control devices
  • shut the system off if there is no gas to the burner

Questão 11

Questão
An operating aquastat is
Responda
  • a safety device that measure if water levels high or low
  • is a device that pumps water when a demand is sent
  • is a a device that activates in response to water change. it is a normally open switch that will open when water reaches desired temperature inside the boiler
  • a device that activates in response to water change . it is a normally closed switch that controls temperature of water inside the boiler

Questão 12

Questão
A combination high limit/fan control is used to
Responda
  • control the speed of the fan for saftey
  • sense flue gas spillage for safety
  • sense air temperature for saftey
  • senses flow of flue gas through pressure switch

Questão 13

Questão
The combination high limit/fan control is a
Responda
  • normally closed switch with a bi metal strip
  • a normally open fan switch with a rod and tube
  • a normally open fan switch with on the left and a normally closed high limit switch on the right
  • a normally open high limit switch on the right and a normally closed fan switch on the left

Questão 14

Questão
An operating pressure switch
Responda
  • actuates in the response of high pressure flue gas temperatures
  • actuates in responce of high temperature in the furnace
  • actuates in response of change of water, steam, air and gas pressure
  • actuates in response clogged flue pipe

Questão 15

Questão
Operating pressure witches are used on
Responda
  • AC units and refrigerators
  • steam boilers. water boilers and combustion burners for gas burners
  • all gas appliances

Questão 16

Questão
An operating pressure switch operates by
Responda
  • releasing steam pressure from the tank as steam rises
  • detects steam pressure and turns off gas to main burner
  • releasing steam pressure from the tank as water rises
  • the switch contacts close and energizes a vent motor to release pressure

Questão 17

Questão
An air flow switch
Responda
  • detects dilution air flow
  • ensures air flow such as flu gasses is bring properly vented with differential air flow
  • ensures that primary, secondary and excesses air is being sent
  • ensures there is no differential air flow

Questão 18

Questão
A flame roll out switch is a high temperature limit switch wired to the burner ignition control. If the flame roll out is sensed the witch is opened and fe-energizes the gas valve.
Responda
  • True
  • False

Questão 19

Questão
When furnaces are equipped with draft hoods, they may be equipped with a shut off system that automatically cuts out the main burner when the vent is blocked. These are refereed commonly and incorrectly reffed to as spill switches
Responda
  • True
  • False

Questão 20

Questão
What takes place in a heat exchange in a forced air furnace
Responda
  • the flue gasses are stored
  • gas and air are mixed
  • the combustion process takes place
  • return air is heated

Questão 21

Questão
inferred haters may not be used in
Responda
  • factories
  • residential
  • warehouses
  • loading docks

Questão 22

Questão
Th purpose of a burner in a forced air furnace is to
Responda
  • supply heat directly to the air in the building
  • heat the combustion air so that the air is lighter to allow it to flow out the exhaust
  • mix the air and gas
  • ignite the gas

Questão 23

Questão
Atmospheric burners are design to operate under
Responda
  • high air pressure with low gas pressure
  • normal atmospheric pressure with low gas pressure
  • atmospheric pressure with high gas pressure
  • compressed air pressure with high gas pressure

Questão 24

Questão
On a roof with a 12/12 pitch and no obstructions the min vent height for a natural gas appliance is
Responda
  • 2'
  • 4'
  • 10'
  • 6'

Questão 25

Questão
On a roof with a 10/12 pitch and a wall 4' high and 6 feet away from the vent opening, what is the minimum height fora category one propane appliance
Responda
  • 6'
  • 2'
  • 3'
  • 10'

Questão 26

Questão
Witch term is used to described the natural draft of the chimney measurements at or near the base of the chimney
Responda
  • static pressure draft
  • neutral pressure point draft
  • base pressure draft
  • chimney draft

Questão 27

Questão
A damper is a
Responda
  • device used to keep the gasket moist and malleable
  • plate or valve for regulating the flow of air or flue gas
  • device used to cool and divert flue gasses
  • fixed flue gas diverter

Questão 28

Questão
Which of the following is an appliance draft control device
Responda
  • a baffle used to control air to a burner
  • a control used to control air for combustion
  • a draft hood or draft regulator
  • a variable damper in the circulating air supply system

Questão 29

Questão
Which burner supplies combustion air at sufficient pressure to overcome the resistance of the burner only
Responda
  • power burner
  • combustion burner
  • forced draft burner
  • fan assisted burner

Questão 30

Questão
What is the name of the device that is installed either internally or eternally to a venting system to extract heat from flue gasses
Responda
  • draft hood
  • heat reclaimer
  • draft control device
  • heat diverter

Questão 31

Questão
Which burner supplies combustion air with a mechanical device such as a fan or blower at sufficient pressure to overcome resistance of the burner at the appliance
Responda
  • forced draft burner
  • high pressure burner
  • fan assisted burner
  • mechanical draft burner

Questão 32

Questão
Which type of appliance has the combustion products or the flue gasses mixed with the medium being heated
Responda
  • direct fired appliance
  • space heater
  • immersion appliance
  • indirect fired appliance

Questão 33

Questão
Which type of appliance does not have flue gasses mixed with the medium being heated
Responda
  • direct fired appliance
  • non vented appliance
  • immersion appliance
  • indirect fired appliance

Questão 34

Questão
Which appliance is constructed so that all the combustion air is supplied directly from and the products of combustion are vented directly to the outdoors by independent passageways connected directly to the appliance
Responda
  • direct vented appliance
  • indoor/outdoor appliances
  • indirect fired appliance
  • direct vent appliance

Questão 35

Questão
An A vent is
Responda
  • double wall vent with aluminum inside used for main vertical shaft or vent connector
  • steel of masonry chimney
  • double wall with stainless steel inside
  • single thickness of galvanized or aluminum

Questão 36

Questão
A B vent is
Responda
  • a steel or masonry chimney
  • a double wall with stainless inside
  • a double wall with aluminum inside
  • double wall with (oval) aluminum inside

Questão 37

Questão
A L vent is a
Responda
  • double wall with stainless inside
  • a single thickness aluminium or galvanized
  • steel or masonry
  • venting system under positive pressure

Questão 38

Questão
A BW vent is a
Responda
  • a single galvanized or stainless
  • double wall with stainless inside
  • double wall (oval) with aluminum inside
  • used for venting systems with positive pressure

Questão 39

Questão
A C vent is a
Responda
  • double wall with stainless inside
  • a single thickness galvanized or stainless
  • double wall (oval) inside with aluminum inside
  • used for vent with positive pressure

Questão 40

Questão
A BH vent is
Responda
  • single thickness wall of galvanized or stainless
  • double wall with stainless inside
  • double wall (oval) inside with aluminum inside
  • venting system under positive pressure

Questão 41

Questão
For venting BH schedule 40 Thermal plastic PVC/CPVC is used
Responda
  • True
  • False

Questão 42

Questão
Three types of thermostats are direct line voltage 120v, 24v and 740ma
Responda
  • True
  • False

Questão 43

Questão
Schedule 40 PVC 636 can be used for temperatures up to 60 C/149 F to
Responda
  • True
  • False

Questão 44

Questão
CPVC can be used up to and including 90C/194F
Responda
  • True
  • False

Questão 45

Questão
The cause of a yellow tipping flame is
Responda
  • the secondary air is reduced
  • the primary air is reduced
  • to much primary air
  • too much dilution air

Questão 46

Questão
The bunsen flame or blue flame is is the result of
Responda
  • no premixing of air
  • perfect secondary air
  • some premixing of primary air
  • no excess air

Questão 47

Questão
Three types of orifices are Fixed, adjustable and universal
Responda
  • True
  • False

Questão 48

Questão
Min and max orifice sizes are
Responda
  • 28-32 drill
  • 29-36 drill
  • 29-42 drill
  • 29-40 drill

Questão 49

Questão
Using ohms law what reading would be giving if each end of the switch was measures
Responda
  • Reading would be 0 or OL
  • reading would be measurable

Questão 50

Questão
Using ohms what reading would be shown on the meter if measurement was taken before and after a load
Responda
  • Infinity (00)
  • measurable

Questão 51

Questão
Most common used wire is romex 14/2
Responda
  • True
  • False

Questão 52

Questão
What does NMD stand for
Responda
  • Non metal dirt resistant
  • Non metal dry
  • Non more drop
  • Non move drip

Semelhante

English Language Techniques
lewis001
Using GoConqr to teach English literature
Sarah Egan
Using GoConqr to study English literature
Sarah Egan
New English Literature GCSE
Sarah Egan
A Level: English language and literature techniques = Structure
Jessica 'JessieB
A Level: English language and literature technique = Dramatic terms
Jessica 'JessieB
The Strange Case of Dr. Jekyll and Mr. Hyde
K d
English Speech Analysis Terminology
Fionnghuala Malone
English Literary Terminology
Fionnghuala Malone
To Kill A Mockingbird GCSE English
naomisargent
Bayonet Charge flashcards
katiehumphrey