Questão 1
Questão
When frisking yourself, after exiting a contamination area, how fast do you move the frisker probe?
Responda
-
1" per minute
-
1/2" per minute
-
1/2" per second
-
2" per second
Questão 2
Questão
When frisking yourself for beta/gamma contamination, after exiting a contamination area, how close do you hold the frisker probe to the surface being frisked?
Responda
-
1 in
-
3/4 in
-
1/2 in
-
1/4 in
Questão 3
Questão
When wearing full protective clothing, where do you locate secondary monitoring device (SMD)?
Responda
-
In the coverall pocket
-
On your lanyard
-
On the wrist
-
On your belt
Questão 4
Questão
When frisking personnel, how many CPM above background is typically considered a minimum level of contamination?
Responda
-
500 CPM
-
300 CPM
-
200 CPM
-
100 CPM
Questão 5
Questão
Which of the below listed dosimetry devices is a Primary Monitoring Device (PMD)?
Questão 6
Questão
A person's dose margin is how much radiation dose a person may be allowed to receive before exceeding an administrative dose limit.
Questão 7
Questão
Any Rad Worker, by virtue of their training, may post radiological areas and/or move radiological postings.
Questão 8
Questão
What type of radiation does protective clothing protect you from?
Responda
-
Beta and Gamma
-
All Types
-
Alpha
-
None of these
Questão 9
Questão
When wearing full PCs, workers may not choose to wear latex gloves instead of rubber gloves.
Questão 10
Questão
When removing protective clothing (hood, coveralls, cloth glove liner, rubber gloves, shoe covers, rubber overshoes), which one of the following items is removed first?
Responda
-
Rubber overshoes
-
Gloves
-
Hood
Questão 11
Questão
When donning a single set of protective clothing, what is the correct position of the shoe cover (bootie)?
Questão 12
Questão
After exiting a Contamination Area, what type of survey should you perform to determine whether or not you have contamination on you?
Questão 13
Questão
It is not common practice in the industry for a PC hood and surgeon's cap (skull cap) to be used interchangeably, based on the preference of the wearer.
Questão 14
Questão
What level of protective clothing is typically required for Rad Workers in a Contamination Area?
Responda
-
Scrubs
-
Full PCs
-
Partial PCs
-
Double PCs
Questão 15
Questão
When using protective clothing, the order in which you remove them is more important than the order in which you put them on.
Questão 16
Questão
What level of protective clothing is typically required for Rad Workers in High Contamination Area?
Responda
-
Scrubs
-
Full PCs
-
Partial PCs
-
Double PCs
Questão 17
Questão
When using a frisker (count rate meter), to detect personnel contamination, what is the maximum background count rate in which the instrument should be used?
Responda
-
100 CPM
-
200 CPM
-
300 CPM
-
500 CPM
Questão 18
Questão
What are the standard units of measure for radioactive contamination on surfaces?
Responda
-
uCi/cc
-
uCi/100cm2
-
DPM/100cm2
-
CPM/100cm2
Questão 19
Questão
A smear typically represents an area of approximately:
Responda
-
100,000 cm2
-
1000 cm2
-
100 cm2
-
10cm2
Questão 20
Questão
You are working in a room within the RCA. You see what appears to be white powder on the valve bonnet. You should think:
Responda
-
Neutron emitters may be present
-
It is residue from stem packing
-
It is likely contaminated
-
It may be cocaine
Questão 21
Questão
When taking contamination surveys, smears typically be taken on floors and on equipment, pipes, or structures.
Questão 22
Questão
Background radiation dose is never subtracted before recording dose rate readings on the survey map.
Questão 23
Questão
What instrument data is typically recorded on a contamination survey map?
Responda
-
ID number
-
Calibration data
-
10% of low scale
-
Response check date
Questão 24
Questão
When documenting a "general area" dose rate survey instrument reading on a survey map, what units are written on the map next to the reading?
Questão 25
Questão
An asterisk on the radiation survey map indicates what?
Responda
-
Hot Spot
-
Beta Reading
-
Contact Reading
-
Neutron Reading
Questão 26
Questão
Which of the following situations would likely involve beta radiation?
Responda
-
A "hot spot" survey of an elbow on a pipe containing reactor coolant?
-
A routine "general area" survey of a heat exchanger room in the RCA
-
A "general area" radiation survey in the reactor building of BWR immediately after reactor shutdown.
-
A radiation survey of a reactor coolant ion exchanger resin spill in the rad waste building
Questão 27
Questão
Name four things you should always do prior to using a radiation detection instrument for assessing radiological contamination.
a[blank_start].[blank_end]
b[blank_start].[blank_end]
c[blank_start].[blank_end]
d[blank_start].[blank_end]
Responda
-
Battery Check
-
Calibration Check
-
Integrity Check
-
Response Check