Certainteed Self-Test Section 6

Descrição

Sales Representative Roofing (Self-Test ) Quiz sobre Certainteed Self-Test Section 6, criado por Connor Sheffield em 20-11-2019.
Connor  Sheffield
Quiz por Connor Sheffield , atualizado more than 1 year ago
Connor  Sheffield
Criado por Connor Sheffield mais de 4 anos atrás
6
0

Resumo de Recurso

Questão 1

Questão
The height of the section of step flashing that is applied against a vertical side surface (wall or chimney) must be at least 2” high, but for additional protection, use step flashing with a greater height.
Responda
  • True
  • False

Questão 2

Questão
It’s okay to fasten the step flashing to cap flashing
Responda
  • True
  • False

Questão 3

Questão
The base flashing used against a vertical front wall must:
Responda
  • Be a continuous piece of metal up to 10’ in length.
  • Be embedded in asphalt plastic cement.
  • Extend up the wall at least 2”.
  • All of the above.

Questão 4

Questão
A cricket:
Responda
  • Projects through the roof and should be handled like a round vent pipe.
  • Helps to prevent a build-up of ice and snow at the uppermost side of the chimney.
  • Is put in position after the underlayment has be applied.
  • Is fastened to the deck with asphalt plastic cement.

Questão 5

Questão
Cap Flashing, continuous counter flashing and surface mounted counter flashing are three flashing methods used on chimneys.
Responda
  • True
  • False

Questão 6

Questão
Base flashing is required at the point where a dormer meets a sloping roof.
Responda
  • True
  • False

Questão 7

Questão
When installing a closed-cut valley, first lay the shingles from the roof with lesser area across the valley and on to the adjoining roof area at least 24 inches.
Responda
  • True
  • False

Questão 8

Questão
Generally, the valley method preferred by Certainteed is the closed-cut method.
Responda
  • True
  • False

Questão 9

Questão
Open valleys are recommended for Grand Manor, Carriage House, Landmark TL, Presidential Shake, and Presidential TL.
Responda
  • True
  • False

Questão 10

Questão
The alternate closed valley application is recommended for 3 tab shingles.
Responda
  • True
  • False

Questão 11

Questão
Flashing a skylight curb requires apron flashing on the base, step flashing on the sides, base flashing on the upslope side, and a kick-out diverter.
Responda
  • True
  • False

Questão 12

Questão
Hemmed edges on flashing that are turned upward create air gaps that resist the movement of moisture from the metal to the roofing.
Responda
  • True
  • False

Semelhante

Test Building Design Roofing
Martin Jones
Certainteed Self-Test Section 3
Connor Sheffield
Certainteed Self-Test Section 5
Connor Sheffield
Certainteed Self-Test Section 2
Connor Sheffield
Certainteed Self-Test Section 4
Connor Sheffield
Carboidratos (glicídios, açucares, hidratos de carbono)
Beatriz Avanzi
Organização e Arquitetura de Computador
Rodrigo Gomes
Vestibular - Guia de Estudos
Alessandra S.
Matemática 9º ano
Carlos Itapecuru
SIMULADÃO EA-HSG EMA-136 NORMAS A RESPEITO DAS TRADIÇÕES NAVAIS, O COMPORTAMENTO PESSOAL E DOS CUIDADOS MARINHEIROS
isac rodrigues
Passe Cursinho - Pré-Vestibular 2016
Passe Cursinho