The scan time for a 3D acquisition is given by:
Responda
  • TR X NEX X phase encodings X number of slices
  • TR X NEX X phase encodings X slice thickness
  • (TR X NEX X phase encodings)/echo train length
  • TR X NEX X phase encodings

Questão 2

Questão
The scan time for a 2D acquisition is determined by:
Responda
  • TR X NEX X phase encodings X FOV
  • TR X NEX X phase encodings X number of slices
  • TR X NEX X phase encodings X slice thickness
  • TR X NEX X phase encodings

Questão 3

Questão
During a conventional spin echo exam, one line of k-space is filled each
Responda
  • frequency encoding period
  • TE period
  • TR period
  • TI period

Questão 4

Questão
Noise represents
Responda
  • current induced in the phase encoding gradient
  • frequencies that exist randomly in space and time
  • frequencies that exist in a structured environment at a specific location
  • Un-captured voltage potential

Questão 5

Questão
Changing the size of a voxel in the frequency direction will
Responda
  • have no effect on the scan time
  • double the scan time
  • increase the scan time by a factor of 0.5

Questão 6

Questão
What is the slice thickness for an isotropic voxel with a 20 cm field of view and a 256 X 256 matrix
Responda
  • 13 cm
  • 0.8 mm
  • 3 cm
  • 1.3 mm

Questão 7

Questão
Where in a spin echo pulse sequence are pre-saturation pulses usually placed?
Responda
  • after the excitation pulse
  • after the 180 degree RF pulse
  • between the 90 degree and 180 degree RF pulse
  • prior to the excitation pulse

Questão 8

Questão
Which of the following TR parameters will provide the highest signal to noise?
Responda
  • 1800 ms
  • 400 ms
  • 2500 ms
  • 800 ms

Questão 9

Questão
Which of the following TE parameters will provide the highest signal to noise?
Responda
  • 120 ms
  • 20 ms
  • 40 ms
  • 80 ms

Questão 10

Questão
Which of the following flip angles will provide the highest signal to noise?
Responda
  • 45 degrees
  • 115 degrees
  • 90 degrees
  • 5 degrees

Semelhante

x-sectional anatomy
Korie Hi
MRI Scans
Heloise Tudor
Imaging in Gynaecology
Matthew Coulson
Medical Physics
Tim Davidson
Diagnostic Imaging Technology
Tashelle Davis
Diagnostic Imaging Technology
Keyria M
Michael Colombini - MRI Case_1
Nikki Davidson
Case 1
Poh Sun Goh
Tipos de Trabalhos Científicos
Rebeca Sales
Farmacologia
B F
Ingleses, franceses e holandeses na América
jacson luft