3b1 3.1 Watertube boiler design

Descrição

Quiz sobre 3b1 3.1 Watertube boiler design, criado por TRAVIS CANNING em 14-01-2016.
TRAVIS CANNING
Quiz por TRAVIS CANNING, atualizado more than 1 year ago
TRAVIS CANNING
Criado por TRAVIS CANNING quase 9 anos atrás
14
1

Resumo de Recurso

Questão 1

Questão
Field erected boilers have outputs of?
Responda
  • 75000 kg/h
  • 100000kg/h
  • 100mg/h
  • 150000kg/h or more

Questão 2

Questão
Feed-water entering the boiler section first passes through the ________ section where it is heated by the combustion gases leaving the boiler.
Responda
  • furnace
  • economizer
  • boiler drum
  • superheater

Questão 3

Questão
Where electric power is used as the heating source, the boiler rating shall be the maximum kilowatt rating of the:
Responda
  • power plant
  • heating element
  • Boiler wiring
  • MCC

Questão 4

Questão
Generally two types of draft fans are used. A ____ ___ fan supplies air to the air preheater. The preheated air for combustion goes to the coal pulverizers and to the burners. An ______ ___ fan exhausts the combustion gases from the air heater to the stack.
Responda
  • center mounted, external mounted
  • forced draft, induced draft
  • induced draft, forced draft
  • turbine draft, ejection draft

Questão 5

Questão
The arrangement of a once through boiler has no drums. The feed water is heated and then evaporated and superheated in _____ _____ through the unit.
Responda
  • Two passes
  • One passage
  • 3 passes
  • 4 passes

Questão 6

Questão
The main advantage of the packaged boiler is its
Responda
  • small size
  • compact design
  • low cost
  • quality steam

Questão 7

Questão
Packaged watertube boilers capacities range from?
Responda
  • 2300kg to 65000kg per hour
  • 500kg to 100mg per hour
  • 15psi to 15000
  • 65000 to 100000 kg per hour

Questão 8

Questão
The advantage of forced circulation in a boiler for a _______ flow in all tubes
Responda
  • negative
  • greater
  • positive
  • mass

Questão 9

Questão
The steam separating equipment separates the _____ from the steam/water mixture
Responda
  • water
  • steam
  • impurities
  • water droplets

Questão 10

Questão
These types of boilers (A,D, and O) have furnaces cooled by _____ lining the furnace walls
Responda
  • watertubes
  • fans
  • desuperheaters
  • air circulation

Semelhante

história do brasil -periodo colonial
Day Almeida
Independência do Brasil.
Marina Amaral
Tabuada
Alessandra S.
Vidas Secas
Alessandra S.
Simulado OAB
Alessandra S.
Aplicações do Mapa Mental
Alessandra S.
CPC-00 - CAPÍTULO 3: CARACTERÍSTICAS QUALITATIVAS DA INFORMAÇÃO CONTÁBIL-FINANCEIRA ÚTIL
Viviana Veloso
Primeiros habitantes do Brasil
luciahelenaferre
Direito Tributário
Lúcio Flávio Lucca
Crise da República e a ruptura de 1930
jacson luft
6° ano - A vida no solo - Capítulo 5
Taína Garcia Moreno Tomazella