Questão 1
Questão
The balance between convective heat transfer and radiative heat transfer can significantly affect the comfort achieved by various heat emitters.
Questão 2
Questão
Finned-tube baseboard convectors operate on the principle that heated air rises due to its lower density.
Questão 3
Questão
As a rule, convectors are well suited for rooms with high ceilings.
Questão 4
Questão
Parallel piping methods allow independent flow rate adjustment for each baseboard.
Questão 5
Questão
When rooms lack the wall space needed to mount finned-tube baseboard, one alternative is to use a hydronic fan-coil.
Questão 6
Questão
The heat output of a fan-coil is approximately proportional to the temperature difference between the entering air and entering water.
Questão 7
Questão
The rate of heat transfer depends on either the temperature difference or the flow rate.
Questão 8
Questão
Panel radiators typically require much more wall space than fin-tube baseboard sized for equivalent heat output and operating conditions.
Questão 9
Questão
Reverse return piping encourages equal flow rates and equal supply temperature to each radiator.
Questão 10
Questão
A rule of thumb is to allow twice the linear footage of radiant baseboard compared to typical residential finned-tube baseboard.
Questão 11
Questão
A typical finned-tube baseboard convector consists of a sheet metal enclosure containing a __________ tube fitted with aluminum fins.
Responda
-
copper
-
PEX
-
cast iron
-
stainless steel
Questão 12
Questão
The heat output of finned-tube baseboard is expressed in Btu/hr./ft. of active element length. The active length of the element is the length of pipe _________.
Questão 13
Questão
When baseboards are connected _________, each receives water at the temperature supplied to the manifold.
Responda
-
in series
-
in parallel
-
with copper tubing
-
to a thermostat
Questão 14
Questão
Hydronic fan-coils have two common components—a(n) __________ heat exchanger (often called the “coil”) through which system fluid flows and a blower or fan that forces air to flow across the coil.
Responda
-
ceramic
-
cast iron
-
open-looped
-
finned-tube
Questão 15
Questão
Increasing the fluid flow rate through the coil will __________ increase the heating capacity of the fan-coil.
Responda
-
greatly
-
never
-
unpredictably
-
marginally
Questão 16
Questão
To prevent corrosion, steel panel radiators should only be used in __________ systems.
Responda
-
open-loop
-
closed-loop
-
parallel
-
hydraulically calibrated
Questão 17
Questão
Operating panel radiators at __________ water temperatures increases the percentage of radiant versus convective heat output from the panel.
Responda
-
lower
-
higher
-
thermally equalized
-
ambient
Questão 18
Questão
The head loss of radiant baseboard can be determined by considering each baseboard to be a tubing circuit approximately _________ as long as the baseboard extrusion.
Responda
-
twice
-
half
-
equally
-
three times
Questão 19
Questão
One way that heat loss of bare copper tube can be evaluated is when the length of the copper tube in feet divided by the flow rate in gallons per minute exceeds __________ ft./gpm, there will be a greater temperature drop along the tube from inlet to outlet.
Questão 20
Questão
Every hydronic heating system attempts to establish operating conditions that allow the distribution system to current rate of heat output from the heat source. This state is known as __________.
Responda
-
hydraulic channeling
-
thermal equilibrium
-
reverse return flow
-