Chapter 8 - Quiz

Descrição

Heat Emitters
Neil Revollo
Quiz por Neil Revollo, atualizado more than 1 year ago
Neil Revollo
Criado por Neil Revollo mais de 8 anos atrás
504
0

Resumo de Recurso

Questão 1

Questão
The balance between convective heat transfer and radiative heat transfer can significantly affect the comfort achieved by various heat emitters.
Responda
  • True
  • False

Questão 2

Questão
Finned-tube baseboard convectors operate on the principle that heated air rises due to its lower density.
Responda
  • True
  • False

Questão 3

Questão
As a rule, convectors are well suited for rooms with high ceilings.
Responda
  • True
  • False

Questão 4

Questão
Parallel piping methods allow independent flow rate adjustment for each baseboard.
Responda
  • True
  • False

Questão 5

Questão
When rooms lack the wall space needed to mount finned-tube baseboard, one alternative is to use a hydronic fan-coil.
Responda
  • True
  • False

Questão 6

Questão
The heat output of a fan-coil is approximately proportional to the temperature difference between the entering air and entering water.
Responda
  • True
  • False

Questão 7

Questão
The rate of heat transfer depends on either the temperature difference or the flow rate.
Responda
  • True
  • False

Questão 8

Questão
Panel radiators typically require much more wall space than fin-tube baseboard sized for equivalent heat output and operating conditions.
Responda
  • True
  • False

Questão 9

Questão
Reverse return piping encourages equal flow rates and equal supply temperature to each radiator.
Responda
  • True
  • False

Questão 10

Questão
A rule of thumb is to allow twice the linear footage of radiant baseboard compared to typical residential finned-tube baseboard.
Responda
  • True
  • False

Questão 11

Questão
A typical finned-tube baseboard convector consists of a sheet metal enclosure containing a __________ tube fitted with aluminum fins.
Responda
  • copper
  • PEX
  • cast iron
  • stainless steel

Questão 12

Questão
The heat output of finned-tube baseboard is expressed in Btu/hr./ft. of active element length. The active length of the element is the length of pipe _________.
Responda
  • under a source of downward drafts
  • nearest the riser's centerline
  • covered with fins
  • in the entire assembly

Questão 13

Questão
When baseboards are connected _________, each receives water at the temperature supplied to the manifold.
Responda
  • in series
  • in parallel
  • with copper tubing
  • to a thermostat

Questão 14

Questão
Hydronic fan-coils have two common components—a(n) __________ heat exchanger (often called the “coil”) through which system fluid flows and a blower or fan that forces air to flow across the coil.
Responda
  • ceramic
  • cast iron
  • open-looped
  • finned-tube

Questão 15

Questão
Increasing the fluid flow rate through the coil will __________ increase the heating capacity of the fan-coil.
Responda
  • greatly
  • never
  • unpredictably
  • marginally

Questão 16

Questão
To prevent corrosion, steel panel radiators should only be used in __________ systems.
Responda
  • open-loop
  • closed-loop
  • parallel
  • hydraulically calibrated

Questão 17

Questão
Operating panel radiators at __________ water temperatures increases the percentage of radiant versus convective heat output from the panel.
Responda
  • lower
  • higher
  • thermally equalized
  • ambient

Questão 18

Questão
The head loss of radiant baseboard can be determined by considering each baseboard to be a tubing circuit approximately _________ as long as the baseboard extrusion.
Responda
  • twice
  • half
  • equally
  • three times

Questão 19

Questão
One way that heat loss of bare copper tube can be evaluated is when the length of the copper tube in feet divided by the flow rate in gallons per minute exceeds __________ ft./gpm, there will be a greater temperature drop along the tube from inlet to outlet.
Responda
  • 5
  • 10
  • 15
  • 20

Questão 20

Questão
Every hydronic heating system attempts to establish operating conditions that allow the distribution system to current rate of heat output from the heat source. This state is known as __________.
Responda
  • hydraulic channeling
  • thermal equilibrium
  • reverse return flow
  • radiant heat output

Semelhante

Coronary 1 Practice
romalsp
Quotes from William Shakespeare's Romeo and Juliet
cecicurtis
Exam Part 1 of Nursing 112 FInal GBCC
Tess Nicholson
Motivational Interviewing
Julie HEYRMAN-COMPERNOLLE
Life Science 7 Final Exam
pcsalazar
AP Environmental Science
sabrinapar22
Obligations and Contracts - Provisions
mitchdeocampo
types of bullying
Gabriela Morales
PBSC BSC1011L Final Exam Study Guide
Emily W
Chapter 11 - Quiz
Neil Revollo
EC201 Final Exam
Zachariah Mann