8 week prep (1)

Description

Fire Academy Quiz on Untitled, created by Jesse Clark on 14/09/2016.
Jesse Clark
Quiz by Jesse Clark, updated more than 1 year ago
Jesse Clark
Created by Jesse Clark about 8 years ago
148
1

Resource summary

Question 1

Question
A joisted floor has one tremendous advantage over the truss floor system: Each joist acts as a _____________.
Answer
  • Web
  • Post
  • Column
  • Fire Stop

Question 2

Question
A party wall is _______ than two separate walls.
Answer
  • Thinner
  • Thicker
  • More Solid
  • Wider

Question 3

Question
A space within a beam where there is neither tension nor compression is known as the?
Answer
  • Vertical plane
  • Horizontal plane
  • Intersected plane
  • Neutral plane

Question 4

Question
A type of collapse that leaves a single triangular void space is?
Answer
  • Lean-to-floor collapse
  • V-shaped floor collapse
  • Cantilever floor collapse
  • Frame floor collapse

Question 5

Question
A(n) _______ code applies to all structures and conditions within them, including existing hazards that were created even before the adoption of the code.
Answer
  • Building
  • Mechanical
  • Fire
  • Electrical

Question 6

Question
All loads of a heavy timber building must be delivered to the ______?
Answer
  • Ground
  • Bearing walls
  • Main supports
  • Wooden columns

Question 7

Question
All of the following are major areas of concern in ordinary construction buildings except
Answer
  • The non-bearing wood walls as a barrier to fire extension
  • The structural stability of the masonry walls
  • Void Spaces
  • The stability of the interior beam systems

Question 8

Question
At about ______ degrees F, steel will begin to elongate.
Answer
  • 600
  • 800
  • 1000
  • 1300

Question 9

Question
Building codes regulate the size and height of structures, based on the construction classification and the __________.
Answer
  • Occupancy type
  • Construction type
  • Building materials
  • Manufacturer recommendations

Question 10

Question
Cold-drawn steel will fail at what temperature?
Answer
  • 400 degrees F
  • 600 degrees F
  • 800 degrees F
  • 1000 degrees F

Question 11

Question
Concrete is a mixture of portland cement, water, and ______.
Answer
  • Aggregates
  • Cement
  • Admixtures
  • Composites

Question 12

Question
Concrete is inherently?
Answer
  • Weak in compression
  • Strong in tension
  • Combustible
  • Non-Combustible

Question 13

Question
Concrete is tested in _______ because it virtually has no tensile strength.
Answer
  • Tension
  • Torsion
  • Compression
  • Pressure

Question 14

Question
Draft stopping consists of plywood, sheet metal, or other approved material and is installed to protect against ________ fire spread.
Answer
  • Horizontal
  • Vertical
  • Forced
  • Opposite

Question 15

Question
Fire fighters are reduced to just reacting to a fire rather than being prepared for its many potential hazards if they do not do what?
Answer
  • Conduct fire inspections
  • Conduct fire prevention programs
  • Conduct safety surveys
  • Conduct pre-fire plans

Question 16

Question
Fire stops typically limit the _______ movement of fire through small, concealed passages.
Answer
  • Horizontal
  • Vertical
  • Forced
  • Opposite

Question 17

Question
Heavy timber construction is a descendent of true ______ construction.
Answer
  • Refined
  • Wood
  • Mill
  • Innovative

Question 18

Question
In the typical downtown ordinary construction building, the side walls are the ________ walls, whereas the front and back walls are ________.
Answer
  • Bearing, non-bearing
  • All are bearing
  • Non-bearing, bearing
  • All are nonbearing

Question 19

Question
In which type of non-combustibel building is the entire structure engineered to act as one unit with the walls and roof structure relying on each other for stability?
Answer
  • Masonry wall with steel bar joist
  • Rigid frame
  • Concrete tilt-up
  • Reinforced masonry

Question 20

Question
It is essential that you have a working knowledge of how buildings are designed, constructed, ________, altered and fall into disrepair.
Answer
  • Renovated
  • Brought up to code
  • Restored
  • Reestablished

Question 21

Question
Masonry walls are no designed to resist?
Answer
  • Concentrated loads
  • increased live loads
  • Lateral impact loads
  • Dead loads

Question 22

Question
Masonry walls in ordinary construction may consist of all of the following except
Answer
  • Concrete block
  • Terra Cotta tile
  • Wood studs
  • Precast concrete

Question 23

Question
One of the major problems with the modification procedures in heavy timber construction is that?
Answer
  • It may create void spaces
  • It creates unsprinklered areas
  • Steel trusses or girders may be used instead of heavy timbers
  • Any of the above

Question 24

Question
Reinfored concrete is a _________ material
Answer
  • Admixture
  • Aggregate
  • Cured
  • Composite

Question 25

Question
Steel cable will have complete failure at _______ degrees F.
Answer
  • 800
  • 600
  • 1000
  • 1200

Question 26

Question
Steel heated to _________ degrees F elongates 9 inches per 100 feet of length.
Answer
  • 1000
  • 1500
  • 2000
  • 2500

Question 27

Question
Steel provides the _______ strength that concrete lacks.
Answer
  • Tensile
  • Torsion
  • Compressive
  • All of the above

Question 28

Question
The bottom chord of a truss is said to be in _______ while the top chord is under ______.
Answer
  • Compression, tension
  • Tension, compression
  • Torsion, compression
  • Tension, Torsion

Question 29

Question
The destruction of the World Trade Center is best described as an example of?
Answer
  • Global collapse
  • Partial collapse
  • Secondary collapse
  • V-shaped floor collapse

Question 30

Question
The stone arch works because all members of the arch are under_______, and little or no tensile load is placed on a material that is weak in tensile strength.
Answer
  • Strain
  • Torsion
  • Compression
  • Tension

Question 31

Question
There are many ways to stabilize a wall in ordinary construction buildings, which of the following is one of these?
Answer
  • Buttresses or mass of masonry outside the wall
  • Pilastrers or colus built inside the wall
  • Wall columns built within the wall
  • Any of the above

Question 32

Question
Spraying water on heated steel is dangerous as it can cause the steel to shatter and fall.
Answer
  • True
  • False

Question 33

Question
What are two methods used fro pre-stressing?
Answer
  • Pre-compression, post compression
  • Pre-tensioning, post-tensioning
  • Pre-releasing, post releasing
  • Pre-stressing, Post-stressing

Question 34

Question
What construction method describes a building where all of the concrete is properly bonded together and acts as one?
Answer
  • Monolithic construction
  • Composite construction
  • Precast construction
  • Fire-resistive construction

Question 35

Question
What is known as the eternal enemy of every building?
Answer
  • Gravity
  • Fire
  • Dead Loads
  • Shock Loads

Question 36

Question
What is the major difference between noncombustible construction and fire resistive construction?
Answer
  • The level of fire resistance
  • the lack of fire suppression
  • The number of floors
  • The materials used for construction

Question 37

Question
When a brick is laid so that the long side is visible, it is referred to as?
Answer
  • Stretcher course
  • Header course
  • Bond course
  • Veneer course

Question 38

Question
When a column is offset, the girder on which it rests becomes a __________ beam.
Answer
  • Transfer
  • Suspended
  • Simple
  • Needle

Question 39

Question
When exposed to fire, plywood will begin to ________.
Answer
  • delaminate
  • corrode
  • flake
  • chip

Question 40

Question
When exposed to heat, steel does all of the following except:
Answer
  • Hardens
  • Elongates
  • Conducts heat
  • Ultimately fails

Question 41

Question
Which item would lessen the code requirements for a given building?
Answer
  • Sprinkler system
  • Standpipe system
  • Fire alarm system
  • none of the above

Question 42

Question
Which type of non-combustible buildings are a cousin to the arch in that they transmit the load as one structure from the roof to the ground?
Answer
  • Rigid Frame
  • Masonry wall with steel bar joists
  • Concrete tilt up
  • Reinforced masonry

Question 43

Question
What type of wall is of a non-load-bearing nature and can carry no other weight than its own?
Answer
  • Curtain Wall
  • Wall-bearing
  • Wooden walled
  • Paneled Wall

Question 44

Question
Why does post-tensioned concrete pose a greater collapse hazard when involved in a construction fire than conventional reinforced concrete?
Answer
  • No bond between the tendons and the concrete
  • Less compressive strength
  • Lower weight to mass ratio
  • All of the above

Question 45

Question
Why would it be beneficial to separate pre-fire planning and the inspection function?
Answer
  • Because inspection are essentially a policing function
  • Because of time constraints
  • Because of inadequate personnel
  • Because of training limitations

Question 46

Question
___________ are concrete pads, usually heavily reinforced, that transfer the loads of piers or columns to the ground.
Answer
  • Footings
  • Caissons
  • Corrugations
  • Foundations

Question 47

Question
__________ are false spaces above built-in cabinets, usually in a kitchen or in the undersides of stairways and projecting eaves.
Answer
  • soffits
  • trimmers
  • battens
  • splines

Question 48

Question
[blank_start]Zoning regulations[blank_end] spell out what types of buildings can be built in specific locations in a city and what they can be used for.
Answer
  • Zoning regulations
  • Building codes
  • Fire codes
  • Construction safety regulations

Question 49

Question
Fire codes are usually the result of lessons learned from the past. Which one of these was the location of the deadliest nightclub fire in history?
Answer
  • Cocoanut Grove - November 28, 1942
  • London Fire of 1666
  • Triangle Shirtwaist Factory Fire - March 25, 1911
  • The Station Club Fire - February 20, 2003

Question 50

Question
For maximum lifesaving coverage, the Boise Fire Department recommends installing smoke detectors in all of the folowing except
Answer
  • Garage areas
  • Each bedroom
  • Every level of your home
  • Every living area

Question 51

Question
If a customer calls your station coplainging that their smoke detector regularly responds to cooking smoke or shower steam, what should you do? All of the following are correct except.
Answer
  • Refer them to fire prevention
  • If ceiling mounted, relocate the unit to a wall, if possible
  • Replace the detector with one that has a silence button feature
  • Move the detector further away to give smoke or steam a chance to dissipate before reacing the unit.

Question 52

Question
If you only had one CO detector to give away to a family in need, where would be the best location according to NFPA 720?
Answer
  • Outside sleeping areas
  • In the bedroom of mom and dad
  • In the infant or child's bedroom
  • In the garage next to the water heater and furnace

Question 53

Question
The City of Boise adopted the 2006 version of International Fire Code through which Title of the municipal code?
Answer
  • Title 7
  • Title 3
  • Title 5
  • Title 9

Question 54

Question
The best location for mounting a smoke detector is where?
Answer
  • Middle of the ceiling
  • On the wall in the corner next to the ceiling
  • Near the heating or cooling ducts
  • In mobile home units, install smoke detectors on outside walls

Question 55

Question
The poison emergency hotline number is?
Answer
  • 1-800-222-1222
  • 1-800-632-8000
  • 1-800-570-6500
  • 1-800-321-1492

Question 56

Question
The radioactive element used to generate alpha particles in Ionization Smoke Detectors is called?
Answer
  • Americium
  • Cadmium
  • Radium
  • Uranium

Question 57

Question
The two main types of smoke detectors available to the public are Photoelectric Smoke detectors and Ionization Smoke Detectors?
Answer
  • True
  • False

Question 58

Question
A particular hazard of the ________ stream, when used for interior firefighting, is that it can actually push the fire with the massive amounts of air that it introduces.
Answer
  • Fog
  • Straight
  • Smooth
  • Combination

Question 59

Question
When considering where to place a carbon monoxide detector, keep in mind that although carbon monoxide is roughly.
Answer
  • Same weight as air
  • Lighter than air
  • Heavier than air

Question 60

Question
An exterior exposure is a building that, if left unprotected could be ignited by all of the following types of heat except
Answer
  • Transient
  • Radiant
  • Conducted
  • Convected

Question 61

Question
Applying water directly to exposures is the ________ effective way of protecting them.
Answer
  • Most
  • Least
  • Partially
  • Slightest

Question 62

Question
Choose the answer that best describes the word size-up.
Answer
  • An evaluation of what is happening
  • Critical description used for structural fire attack only
  • Specific firefighting procedures performed by company officers to meet the strategic goals
  • Method of extinguishment

Question 63

Question
Important points that a firefigther should gain from initial reports from the first arriving unit are all of the above except.
Answer
  • Map page and directions
  • Location of fire in a building and severity
  • Size and height
  • Report of trapped victims

Question 64

Question
In order to minimize costs and maximze profits restaurants are often _________ constructed buildings
Answer
  • Lightweight
  • Heavyweight
  • Platform
  • Ordinary

Question 65

Question
Offensive strategies can be used _____________
Answer
  • When an aggressive interior search can save lives
  • If it is determined that no savable life is present
  • If the building is unsafe due to heavy fire involvment
  • If no items are salvage due to damage and fire

Question 66

Question
One good tactic for suppressing a dumpster fire is to ______________
Answer
  • fill the container with water
  • let it burn itself out
  • fill it full of foam from a CAFs system
  • None of the above

Question 67

Question
Opening _________ after the initial fire attack must be done quickly to search for hidden fire.
Answer
  • Floors and ceilings
  • Windows and doors
  • Drywall and windows
  • Doors and Walls

Question 68

Question
Protecting exposures is one of many steps for a successful fire attack.
Answer
  • True
  • False

Question 69

Question
Strip malls are a modern version of the __________
Answer
  • Taxpayer
  • Mega Malls
  • Tavern
  • Big Box stores

Question 70

Question
The first 50 feet of hoseline being stretched into the structure on fire is referred to as the _________.
Answer
  • Working Line
  • Kill length
  • First Stretch
  • Dead load

Question 71

Question
The most proven stream (and safest for firefighters) for interior fire attack is a ___________ stream
Answer
  • Straight or solid
  • Fog or combination
  • Solid or fog
  • Solid or stiff

Question 72

Question
The nozzle operator is responsible for _______________
Answer
  • bleeding air at the door
  • backing up the officer
  • hooking the hydrant
  • backing up the officer in a stairwell

Question 73

Question
The standard search-and-rescue plan uses the ________-team approach
Answer
  • two
  • one
  • three
  • four

Question 74

Question
Vetical ventilation is the act of opening a hole in the ________ to allow the products of combustion, smoke, and heat to leave the building.
Answer
  • Roof
  • Window
  • Sliding door
  • Wall

Question 75

Question
What is the best way to prevent "water hammer"?
Answer
  • Open and close nozzles slowly
  • Use spanner wrenches to tighten couplings
  • There is no best way
  • Use lower hose pressure

Question 76

Question
What problems could occur in the event of a "water hammer"?
Answer
  • Damage to the hoseline and pumper
  • Pressures decreases on the attack crew's hoseline
  • If a firefighter get hit direct with this, they could be severly injured
  • The pump on the pumper may cavitate

Question 77

Question
Why must the nozzle team remain low upon initial entry into the door of the fire building?
Answer
  • To allow smoke and heat to vent over their heads
  • There is no need to remain low upon entry
  • So the door firefighter can see the door they are opening.
  • None of the above

Question 78

Question
A _________ is the development and implementation of a plan, incorporating specific goals, to bring a fire under control.
Answer
  • Strategy
  • Tactic
  • Goal
  • Coordinated attack

Question 79

Question
When using common terminology for structures, divisions A, B, C and D depict different sides of a building. With side A usually being the side of the building with the main entrance that faces the street, which way is side B?
Answer
  • Clockwise from side A
  • Counterclockwise from side A
  • Right of side A
  • None of the Above
Show full summary Hide full summary

Similar

8 week prep (2)
Jesse Clark
4 week test
Jesse Clark
4 week test continued
Jesse Clark
Hitler Becoming Fuhrer
c7jeremy
BTS - Fire lyrics quiz for Korean Learners
Eunha Seo
Fire Extinguishers Mind Map
Oliver Balay
Significant Dates on Calander and Years
Corey Lance
The Reichstag Fire
Aaishah Din
Essay 4 / Mari
marisusannahalmi
ESSAY 6 ANATOL GROSSE: Study of penguin social behaviour
grosseanatol