Question 1
Question
According to BFD SOP 204.08, a RIT team will consist of a minimum of ________ company(s) or ________ member(s) and designated as RIT.
Answer
-
1 company, 3 members
-
3 companies, 1 member
-
1 company, 4 members
-
2 companies, 6 members
Question 2
Question
"2 in/2 out" does not apply in a rescue situation.
Question 3
Question
A clear strobe is to be marked for egresses only.
Question 4
Question
A truss assembly can fail in ____________ minutes under flame impingement.
Question 5
Question
According to SOP 204.05 all crew/team members must always be in contact with each other through what method(s):
Answer
-
All of these
-
Voice
-
Visual
-
Touch
-
Voice and Touch only
Question 6
Question
Accountability is the responsibility of whom?
Question 7
Question
Failure to read the building and failure to read the fire are two factors that contribute to firefighters getting into trouble.
Question 8
Question
Failure to recognize the presence of truss roofs and floors, failure to chock a door, improper ventilation, and combining offensive and defensive attacks are examples of _____________.
Question 9
Question
In the hand tools pocket of a BFD RIT Kit you will find a pair of ___________ and a pair of _____________.
Answer
-
10" cable cutters, 10" vise grips
-
10" cable cutters, 10" pliers
-
10" vise grips, 10" channel locks
-
10" channel locks, 10" pliers
Question 10
Question
In the ropes pocket in a BFD RIT Kit you will find 2 white sections of rope. Each rope is __________ in length.
Question 11
Question
It is acceptable to turn down an assignment that is beyond your capabilities.
Question 12
Question
Kinks in a hoseline can reduce water volume up to ____________%.
Question 13
Question
Lack of staffing is a leading contributing factor to firefighter injuries and death.
Question 14
Question
MIL SPN stands for: M - Mayday, I - _____________, L - Location
S - __________, P - Plan, N - Needs
Answer
-
Identifier, Situation
-
Identifier, Station
-
Individual, Situation
-
Identifier, Safety
Question 15
Question
NFPA 1404 states firefighters will be allowed to operate with less than 1/4 tank of reserve air in IDLH environment if they are near an exit.
Question 16
Question
On the average, there are approximately _________ firefighter line-of-duty deaths (LODD) per year in the United States.
Question 17
Question 18
Question
Risk assessment is a process used for the initial incident.
Question 19
Question
The Standard on the Fire Department Occupational Safety and Health Program is outlined in NFPA ________.
Question 20
Question
The use of lifeline is necessary when conducting search operations.
Question 21
Answer
-
Drag rescue device
-
Drop rope device
-
Drop rescue device
-
Dead rappel drag
Question 22
Question
Which of the following can RIT do to improve firefighter safety?
Question 23
Question
Which of the following is not part of the three priorities of fireground operations?
Answer
-
Public Information
-
Life safety
-
Incident stablization
-
Property conservation
Question 24
Question
Who has the emergency authority to alter, suspend, or terminate any operation he or she deems hazardous to the operating personnel?
Question 25
Question
"Once combat is joined, one must bring overwhelming force to bear upon the enemy in an extremely rapid manner to ensure the highest likelihood of victory in the shortest duration," best describes which doctrine?
Question 26
Question
High-rise residential, commercial, and industrial structures require a larger volume hand line to adequately combat fire. 2 1/2-inch hose can be aggressively advanced as a hand line while producing how many gallons per minute?
Answer
-
250 gpm
-
150 gpm
-
350 gpm
-
450 gpm
Question 27
Question
2 1/2-inch hose paired with a 1 1/8-inch smooth bore tip produces a user friendly, offensive, large caliber weapon. This combination provides all of the advantages except _______________.
Answer
-
Massive water vaporization
-
Low friction loss per 50-foot length
-
Exceptional penetrating power
-
Easily reduced to smaller hand line
Question 28
Question
A dangerous potential of the adjustable gallonage fog nozzle is that it can produce:
Answer
-
Less than acceptable minimum water flow
-
High nozzle reaction force
-
High friction loss
-
Less than acceptable maneuverability
Question 29
Question
A large volume nozzle that is similar to a detachable deck gun but is always used on the ground is known as a _________________.
Answer
-
Deluge gun (PMS)
-
Water Monitor
-
Water turret
-
Play pipe
Question 30
Question
A piercing nozzle can be used to apply water inside hidden spaces such as walls and floor void spaces.
Question 31
Question
A smooth bore nozzle produces a stream that is characterized by small droplets of water in a dispersed pattern that evaporate more readily, generating steam.
Question 32
Question
A well planned hose and nozzle combination should deliver between _________________ with relatively low friction loss.
Answer
-
150 & 180 gpm
-
75 & 125 gpm
-
100 & 175 gpm
-
175 & 200 gpm
Question 33
Question
After sweeping the overhead area of a fire room, the stream should be swept across the floor to cool the hot water runoff from the ceiling, as well as __________________________.
Answer
-
Blow debris out of the path of your advance.
-
Cool the carpet to protect it from further damage
-
Provide a cool area to kneel down before moving further
-
Provide a clear view of victims that may impeded your progress
Question 34
Question
By using a baffle and spring design inside this nozzle, approximately 100 psi nozzle pressure is maintained. This provides the appearance of an adequate stream with good reach but may not truly be producing proper water volume needed for fire extinquishment. This best describes which fog nozzle.
Answer
-
Automatic fog
-
Adjustable gallonage
-
Constant gallonage
-
Variable ratio
Question 35
Question
During defensive operations a 2 1/2-inch hose line is a much safer alternative because its reach allows it to be operated outside of the collapse zone. However, it is much less mobile and more difficult to place than a master stream device.
Question 36
Question
Elevated master stream devices such as water monitors or ladder pipes allow firefighters to safely apply water from above or through an upper-floor window.
Question 37
Question
Exposure protection lines should provide what benefit?
Answer
-
Maximum reach to keep firefighters out of collapse zones
-
Minimal reach to avoid deploying too much hose
-
Minimal water to reduce water damage
-
Maximum number of firefighters performing some work function
Question 38
Question
Exposure protection requires that water be applied to an exposure surface in order to keep it cooled below its ignition temperature.
Question 39
Question
Flow rates of nozzles today are required to be much higher because ____________.
Answer
-
The type and loading of fuels is much greater than it used to be.
-
Firefighters are not trained in the same tactics as before.
-
Fire engines do not pump the same as they used to.
-
Nozzle design does not distribute water like before.
Question 40
Question
Heavy, thick, black, pressurized, angry smoke is an indication of rapidly deteriorating conditions. what is the proper actions for the nozzle team at this time?
Answer
-
Open the nozzle and begin sweeping back and forth across the ceiling in front of you.
-
Back the hose out of this room and seek an alternate entry point.
-
Advise the pump operator to increase the water pressure.
-
Close the door to this area and await further instructions from your incident commander.
Question 41
Question
Hose should be stretched dry as far as is safely possible to expedite placement prior to being charged. When advancing through doorways what action must be taken?
Answer
-
Securely chock the door open to avoid it closing on a dry hose line.
-
Advance at least twice the amount of line you think is needed to reach the fire.
-
Allow the company officer to pass through ahead of the line.
-
Mark the door with high visibility tape in case a rapid exit is needed.
Question 42
Question
If staffing levels allow, the engine company officer is more effective if he is doing what?
Answer
-
All of these
-
Positioned to the side of the line and opposite the nozzle person
-
Not physically taking part in handling the line
-
Out ahead of the nozzle to perform reconnaissance of the fire
-
Ascertaining forcible entry and life hazard problems
Question 43
Question
Keeping down low, on both knees ______________________________.
Answer
-
Places one at higher risk of knee burn injuries
-
Provides far greater traction and power
-
Provides greater forward momentum and traction
-
Provides a very stable body position
Question 44
Question
Mechanical and hydraulic ventilation through the use of a fog nozzle is less effective than using fans because it does not move as much air.
Question 45
Question
Nozzle reaction is measured in pounds of force and is a function of which two factors?
Answer
-
Flow rate and nozzle pressure
-
Friction loss and nozzle pressure
-
Flow rate and friction loss
-
Friction loss and hose size
Question 46
Question
Once the hose is properly stretched and flaked out, the pump operator is notified to charge the line. Prior to entering the fire area the nozzle person "bleeds the line" to expel trapped air an determine that they have sufficient water flow and pressure.
Question 47
Question
Operating master stream devices outside of their specified range of operation can result in all of the following except ________________________.
Question 48
Question
Overhaul is one of the more dangerous times in a fire building because _______________.
Answer
-
All of these
-
Fire may have weakened the structural stability of the building.
-
There may be the added weight of the lived load of water in clothing and furniture.
-
Fire may be hidden in walls and ceilings.
Question 49
Question
Prior to operating the nozzle, which body position should the nozzle operator avoid at all cost?
Answer
-
Leaning backward or sideways opposite the expected nozzle reaction
-
Leaning forward into the direction of the nozzle reaction
-
in the classic "duck walk" position
-
Feet in contact with the floor, weight distributed mostly on the toes and balls of your feet.
Question 50
Question
Standpipe system operations are often plagued by poor maintenance, lack of proper inspections, pressure-reducing valves that are not adjustable, and debris stuffed in the inlet connections. This has brought many department to rely upon what size hose and nozzle combination for high-rise standpipe operations?
Answer
-
2 1/2 inch hose with a smooth bore nozzle
-
1 3/4 inch hose with a constant gallonage fog nozzle
-
2 inch hose with an adjustable gallonage fog nozzle
-
3 inch hose with an automatic fog nozzle
Question 51
Question
Sweeping the ceiling with large amounts of water out front and overhead through the superheated fuel-laden smoke will cause the phenomenon known as flashover.
Question 52
Question
The Bresnan distributor nozzle is used primarily for what type of fire?
Answer
-
Basement fires
-
Car fires
-
Grass/brush fires
-
Dumpster fires
Question 53
Question
The backup person on a nozzle team provides what benefit to the nozzle person:
Answer
-
Most of the physical labor and momentum
-
Access to each doorway
-
Kinks the hose as needed to turn corners
-
Allows the nozzle person to take most of the nozzle reaction force
Question 54
Question
The classic "duck walk" position keeps firefighters low with their knees off the floor.
Question 55
Question
The direct method of fire attack is to apply a solid or straight stream of water directly onto the burning object. This is best used when ______________.
Answer
-
A single object or small number of objects are burning.
-
A entire compartment is on fire.
-
Several objects of similar material are burning.
-
At least three firefighters are available to advance the hose line.
Question 56
Question
The door position on an attack hoseline provides what function?
Answer
-
Ensures a smooth and sustained movement of hose toward the fire
-
Ensures that the entry door is not blocked for emergency egress
-
Ensures that the hose team does not get lost of disoriented
-
Ensures that the nozzle team is moving toward the seat of the fire
Question 57
Question
The doorway used for access of the initial attack line may be the first ventilation opening to which the fire has access. As such, it is beneficial for the team to do what after opening the door?
Answer
-
Pause briefly to allow the pressurized products of combustion to diminish.
-
Bleed the hose line of entrapped air and debris.
-
Done their SCBA facepiece and test the emergency bypass.
-
Have a forcible entry tool ready to chock the door open.
Question 58
Question
The indirect method of fire attack theory, using fog nozzles, developed during World War II had three key tenets that had to be met in order effectively extinguish fire. Which of the following is not one of these tenets?
Answer
-
Ventilation must be provided prior to beginning water flow
-
There must be no life hazard within the fire compartment
-
The ceiling temperature must have reached at least 1000 degrees Fahrenheit in order to efficiently convert water fog to steam
-
The water fog must be remotely injected into the compartment from the exterior
Question 59
Question
The minimum acceptable flow rate for interior structural fire attack is ________________.
Answer
-
150 gpm
-
95 gpm
-
125 gpm
-
250 gpm
Question 60
Question
The mnemonic memory aid ADULTS refers to scenarios requiring the use of 2 1/2 inch lines. All of the following are correct except __________________.
Answer
-
Trash/debris removal
-
Advanced fire on arrival
-
Defensive operations
-
Unable to determine size of fire area
-
Large, un-compartmented areas
-
Standpipe system operations
Question 61
Question
The most low tech nozzle with the least complicated design and fewest moving parts best describes which nozzle?
Answer
-
Smooth bore
-
Constant gallonage
-
Adjustable gallonage
-
Constant pressure
Question 62
Question
The nozzle is the tool at the very heart of the entire fireground operation. It provides which of the following functions?
Answer
-
All of these
-
Creates shape
-
Controls flow
-
Provides reach
Question 63
Question
Typically, fog nozzles have a rotational control to adjust the pattern from straight stream to wide-angle fog spray. Rotating this control from left to right will change the pattern from wide-angle fog to narrow fog, to straight stream.
Question 64
Question
Under most circumstances, in a typical room and contents fire in low rise one and two family homes, which size hand line is sufficient for proper water flow?
Answer
-
1 1/2 - 2 inch
-
3/4 - 1 inch
-
2 1/2 - 3 inch
-
3 1/2 - 4 inch
Question 65
Question
Useful in indirectly attacking a fire in unoccupied spaces, water's expansion from a liquid to steam can quickly smother a fire. The approximate expansion rate is _________________.
Answer
-
1700 times
-
212 times
-
500 times
-
970 times
Question 66
Question
Using only one moving part, the smooth bore nozzle provides what advantage over fog nozzles?
Answer
-
All of these
-
Difficult to clog
-
Requires the least maintenance
-
Has the longest service life
-
Requires the least amount of training for pump and nozzle operators to become proficient
Question 67
Question
Water turns to steam at 212 degrees Fahrenheit absorbing an additional 970 BTUs. This process is known as _______________.
Answer
-
Latent heat of vaporization
-
Latent heat of absorption
-
Latent heat of expansion
-
Latent heart of pressurization
Question 68
Question
When cleaning and inspecting nozzles after use you should check to see that ______________.
Question 69
Question
When using hydraulic ventilation, what safety precaution should be taken?
Answer
-
Watch for changes in smoke and heat conditions.
-
Avoid excessive water damage to the window or door frames.
-
Watch for excessive water use during drought conditions.
-
Watch for damage of property beneath the vent window.
Question 70
Question
Which of the following are examples of large, un-compartmented areas, with wide-open floor plans?
Answer
-
All of these
-
Bowling alleys
-
Supermarkets
-
Warehouses
-
Churches
Question 71
Question
Which of the following is not the correct placement of the hose for the nozzle operator position, after opening the bale?
Answer
-
Which of the following is not the correct placement of the hose for the nozzle operator position, after opening the bale?
-
On the side of nozzle operator's dominant arm.
-
Hose is placed well into the armpit of the rear arm.
-
The forward hand is moved back from the bale behind the last male hose butt.
Question 72
Question
Which of the following regarding water is correct?
Answer
-
All of these.
-
It extinguishes fire primarily through cooling.
-
It is readily available and inexpensive.
-
If applied to unburned fuel surrounding a fire it makes it difficult for the fire to spread.
Question 73
Question
An essential component of your PPE when dealing with glass is ______________.
Answer
-
A dust mask
-
SCBA
-
A center punch
-
Coveralls
Question 74
Question
Batteries should be disconnected but the keys can be left in the ignition switch.
Question 75
Question
Hybrid high-voltage systems are ground to the vehicle.
Question 76
Question
Making a relief cut in the fender crumple zone is part of what evolution?
Answer
-
Dash lift
-
Steering wheel lift
-
Limo door removal
-
Dash roll
Question 77
Question
Most vehicles are now built with _________________ construction because it is strong and lightweight.
Answer
-
Unibodied
-
Heavy duty
-
Split axle
-
Complex
Question 78
Question
Newer vehicles of today have ultra-strength materials inside the B posts.
Question 79
Question
Next to EMS calls, what is the most common call a department responds to?
Answer
-
Vehicle collisions
-
Structure fires
-
Technical rescues
-
Nuisance calls
Question 80
Question
Power hydraulic tools have operating pressures from _____________.
Answer
-
3,000 - 10,500psi
-
10,000 - 20,000 psi
-
500 - 1,000 psi
-
1,000 - 3,000 psi
Question 81
Question
Stabbing or cutting of the tires on vehicles is a highly recommended way of stabilizing vehicles.
Question 82
Question
The medical trauma care of patients begins with good ______________.
Question 83
Question
There are several types of fuels used in vehicles and all their hazards are listed in the Emergency Response Guide. Some may also be downloaded from the manufacturer's website.
Question 84
Question
There is usually a small window of time to get the patient to the hospital, so extrication should be accomplished in ____________ minutes.
Question 85
Question
This term describes that elapsed time between the time the patient is injured and the time the patient arrives at the hospital for surgery.
Answer
-
Golden hour
-
Reflex time
-
Rescue window
-
Time chain
Question 86
Question
Vehicle stabilization is a critical part of extrication and must be considered at all MVC's.
Question 87
Question
Voltage of the battery is not the greatest concern with vehicles; it is the _______________ of the battery.
Answer
-
Location
-
Size
-
Weight
-
Amperage
Question 88
Question
What are some of the SRS spaces in vehicles that are of concern for rescue personnel?
Question 89
Question
What is the greatest concern when dealing with vehicle voltage?
Answer
-
Finding the battery
-
High Voltage
-
Opening the hood
-
Orange cables
Question 90
Question
When a handline is pulled on an MVC it must be capable of a minimum 100 gpm for adequate fire protection.
Question 91
Question
when tempered glass is cut out, it generates a lot of dust.
Question 92
Question
Which of the following is the most common design construction in production vehicles?
Answer
-
Unibody
-
Bird cage or roll cage
-
Space-frame
-
Full frame
Question 93
Question
Which of the following is true?
Answer
-
Some hybrids generate 110 volts of alternating current.
-
When shut down there is no voltage in the HV battery.
-
You must always disconnect HV battery at a scene.
-
Shutting down the HV disconnects 12v system.