Class D Wastewater Sample Questions

Beschreibung

Wastewater Wastewater Treatment Study Material Quiz am Class D Wastewater Sample Questions, erstellt von Dean Lampman am 16/12/2017.
Dean Lampman
Quiz von Dean Lampman, aktualisiert more than 1 year ago
Dean Lampman
Erstellt von Dean Lampman vor mehr als 6 Jahre
58
1

Zusammenfassung der Ressource

Frage 1

Frage
What Is not run on raw influent wastewater?
Antworten
  • CBOD
  • FECAL Coliform
  • Suspended Solids
  • pH

Frage 2

Frage
What disease is not considered to be conveyed or transmitted by untreated wastewater?
Antworten
  • Amoebic Dysentery
  • Hepatitis
  • Malaria
  • Cholera

Frage 3

Frage
What effect will the addition of chlorine, acid, alum. carbon dioxide, or sulfuric acid have on the pH of wastewater?
Antworten
  • Neutralize
  • Lower
  • Increase
  • Have no effect

Frage 4

Frage
Coliform bacteria are
Antworten
  • Algae
  • Coagulant aids
  • Indicators
  • Sequestering agents

Frage 5

Frage
Which of these pH readings indicates an acidic wastewater?
Antworten
  • 3
  • 7
  • 9
  • 12

Frage 6

Frage
Three waterborne diseases are
Antworten
  • Mumps, measles, colds
  • Scarlet fever, pneumonia, hay fever
  • Typhoid fever, dysentery, cholera
  • TB, diptheria, chickenpox

Frage 7

Frage
Which one of the following conditions increase chlorine demand?
Antworten
  • Alkalinity
  • Increase in organic matter
  • Increase in phosphate
  • pH increase

Frage 8

Frage
A chlorine leak can be detected by
Antworten
  • An explosimeter
  • Checking the leak guage
  • Spraying water on suspected leaks
  • A white cloud in presence of ammonia fumes

Frage 9

Frage
Turbidity in wastewater is caused by
Antworten
  • Finely divided suspended material
  • Dissolved calcium
  • Hardness
  • Color

Frage 10

Frage
Dark tan and shiny foam is produced when
Antworten
  • F/M ratio is too low
  • Insufficient aeration tank capacity
  • Young Sludge
  • RAS rate inappropriate

Frage 11

Frage
The pH of wastewater
Antworten
  • Always increases as acid concentrations increase
  • Always increases when wastewater becomes septic
  • is measured on a scale of 0 to 14
  • is measured on a scale of 0 to 100 mg/L

Frage 12

Frage
Which of the following conditions are likely to have been caused by biological activity that is prompted by long, sluggish flow in a flat grade sewer line?
Antworten
  • Concrete and metal corrosion
  • Oxygen deficiency in manholes, sewers, and wet-wells
  • Toxic gas production
  • All of the answers

Frage 13

Frage
Sand, silt, and grit are composed of what kind of matter?
Antworten
  • Colloidal
  • Inorganic
  • Organic
  • Volatile

Frage 14

Frage
Which of the following statements is NOT indicative of fresh wastewater?
Antworten
  • Contains some dissolved oxygen from the water supply
  • is being decomposed by facultative bacteria
  • is blackish in color, with rotten egg odor
  • is turbid with solids in suspension

Frage 15

Frage
How much does a gallon of water weigh?
Antworten
  • 9.34 lbs
  • 8.34 oz
  • 7.5 lbs
  • 8.34 lbs

Frage 16

Frage
Organic solids in wastewater are
Antworten
  • Generally of vegetable and animal origin
  • Inert and not subject to decay
  • Mostly floatable solids
  • Always settleable solids

Frage 17

Frage
The purpose of primary sedimentation is to remove
Antworten
  • Pathogenic bacteria
  • Roots, rags, cans, and large debris
  • Sand and gravel
  • Settable and floatable material

Frage 18

Frage
One cubic foot of water contains how many gallons?
Antworten
  • 2.31 gallons
  • 7.48 gallons
  • 8.34 gallons
  • 10 gallons

Frage 19

Frage
The seepage of groundwater into sewer lines through cracks and open joints is called
Antworten
  • Inflow
  • Infiltration
  • A blessing in disguise
  • Sanitary sewage

Frage 20

Frage
The direct flow of rainwater into a sewer line through ground level openings and breaks is
Antworten
  • Inflow
  • Infiltration
  • Industrial sewage
  • Sanitary sewage

Frage 21

Frage
_______________ is the most common and prevalent odorous gas associated with domestic wastewater collection systems.
Antworten
  • Chlorine
  • Hydrogen sulfide
  • Carbon dioxide
  • Methane

Frage 22

Frage
Which of the following factors could cause a demand for more DO (Increase in aeration rate) in an aeration tank?
Antworten
  • Increase in food (BOD) in the aeration tank influent
  • Decrease in organic wastewater
  • Increase in influent DO
  • Increase in toxic substances

Frage 23

Frage
Chlorine is _____ times heavier than air
Antworten
  • 1.5
  • 2.0
  • 2.5
  • 3.0

Frage 24

Frage
The liquid to gas expansion ration of chlorine is
Antworten
  • 25 to 1
  • 250 to 1
  • 460 to 1
  • 500 to 1

Frage 25

Frage
Gaseous chlorine is a
Antworten
  • Clear colorless gas
  • White fog-like gas
  • Greenish-yellow gas
  • Greyish-white gas

Frage 26

Frage
In an aerator, a white billowing foam indicates
Antworten
  • The need to increase wasting
  • The need to increase the return activated sludge rate
  • The need to decrease wasting
  • The need to stop the return activated sludge

Frage 27

Frage
In the aerator, the dissolved oxygen should be maintained at what level?
Antworten
  • 2.0 mg/L
  • 5.0 mg/L
  • 6.0 mg/L
  • 8.0 mg/L

Frage 28

Frage
A low F/M ratio, high MCRT, low SVI, and high MLSS concentrations are all characteristic of
Antworten
  • A bulking sludge
  • A young sludge
  • An old sludge
  • None of the answers

Frage 29

Frage
A Class D operator shall not be the lead/chief operator of more than ______ wastewater treatment plant(s) at any time.
Antworten
  • 1
  • 2
  • 5
  • 10

Frage 30

Frage
Where chlorine is used for basic disinfection, a total chlorine residual of at least 0.5 mg/L shall be maintained after at least _____ minutes contact time at maximum daily flow.
Antworten
  • 15
  • 30
  • 45
  • 60

Frage 31

Frage
The operator must report the FDEP any serious breakdown or malfunction within what time frame?
Antworten
  • 24 hours
  • 48 hours
  • 12 hours
  • Immediately

Frage 32

Frage
The recommended storage temperature for preserving samples is
Antworten
  • 21° C
  • 4° C
  • 60° F
  • 32° F

Frage 33

Frage
Employee hazards you might encounter around a treatment facility would be
Antworten
  • Noxious or toxic gases
  • Physical injuries
  • Oxygen deficiency
  • All of the answers

Frage 34

Frage
Chlorine gas is
Antworten
  • Colorless
  • Heavier than air
  • Nontoxic
  • Odorless

Frage 35

Frage
Chlorine is primarily used to
Antworten
  • Disinfect
  • Prevent corrosion
  • Raise pH
  • Stabilize organics

Frage 36

Frage
The exhaust fan inlet in a chlorinator room and/or chlorine storage room should be taken from
Antworten
  • Anywhere - the location is not important
  • At floor level
  • Close to the entrance
  • In the ceiling
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Operation of Wastewater Treatment Plants Volume 2 Review
Dean Lampman
General Wastewater Knowledge
Dean Lampman
Die Aufklärung (Karteikarten)
AntonS
Englisch Vokabeln
anna.grillborzer0656
SMART Lernziele
barbara91
Industrielle Revolution und soziale Frage
bibi97
Vetie Radiologie Vorlesungsfragen
Sophie Lütkemöller
Vetie - Pharma 2018
Fioras Hu
Gesko A: Theorien und Praxis des Journalismus
Johanna Wojcik
Onlinequiz zu MS-4.2 Kapitel_2_Teil_II
Deborah Büscher
Vetie - Milchkunde 2011
steff Müller