ER-2720 assignment

Beschreibung

Quiz on ER-2720, created by Kaitlyn Hickey on 03/02/2018.
Kaitlyn Hickey
Quiz von Kaitlyn Hickey, aktualisiert more than 1 year ago
Kaitlyn Hickey
Erstellt von Kaitlyn Hickey vor mehr als 6 Jahre
30
3

Zusammenfassung der Ressource

Frage 1

Frage
Which schematic diagram represents a heating thermostat?
Antworten
  • NC temperature-actuated switch
  • NO temperature-actuated
  • NC liquid level-actuated switch
  • NO liquid level-actuated switch

Frage 2

Frage
What are the two types of electrical diagrams used in the heating and cooling industry?
Antworten
  • Power and control
  • Schematic and wiring
  • Power and wiring
  • Control and power

Frage 3

Frage
What is best use to demonstrate how electrical circuits works?
Antworten
  • Schematic diagram
  • Wiring diagram
  • Power source diagram
  • Control diagram

Frage 4

Frage
Which diagram is used to find the physical location of a component?
Antworten
  • Schematic diagram
  • Wiring diagram
  • Power source diagram
  • Control diagram

Frage 5

Frage
A device that reacts to changes in a variable-condition is referred to as?
Antworten
  • A relay device
  • An igniting device
  • A load device
  • A controlling device

Frage 6

Frage
An example of a load device is
Antworten
  • Thermostat
  • Limit switch
  • Fan switch
  • Gas valve

Frage 7

Frage
What is an example of a limit safety control device?
Antworten
  • High limit switch
  • High temperature switches
  • Low-pressure switch
  • All the above

Frage 8

Frage
Power supplies if 24 volts, are used to operate what part of the system?
Antworten
  • The power circuit
  • The control circuit
  • The protection circuit
  • The thermocouple circuit

Frage 9

Frage
When does a gas fired furnace in a single-dwelling require a disconnect switch?
Antworten
  • Always
  • Not required
  • As required by section 26 in the CEC
  • As required by section 16 in the CEC

Frage 10

Frage
Is a residential furnace allowed to have a light in the furnace room on its supply circuit?
Antworten
  • Yes
  • No

Frage 11

Frage
What section of the CEC deals with the control circuit wiring?
Antworten
  • Section 16
  • Section 26
  • Section 28
  • Section 32

Frage 12

Frage
What are the most commonly used types of temperature-sensing devices?
Antworten
  • Bimetal temperature-sensing elements
  • thermistors
  • RDT’s
  • Pyrometer’s

Frage 13

Frage
Which type of temperature-sensing device is best used to operate large snap action contacts such as line voltage thermostats?
Antworten
  • Strip type bimetal temperature-sensing element
  • Spiral type bimetal-sensing device
  • Liquid bulb type
  • Bellows type temperature-sensing devices

Frage 14

Frage
What type of temperature sensing device is especially suitable for pipes or tanks
Antworten
  • Bellows type
  • Liquid bulb type
  • Thermocouple
  • Thermistor

Frage 15

Frage
A thermocouple generates a typical voltage of?
Antworten
  • 20mv
  • 30mv
  • 40mv
  • 50mv

Frage 16

Frage
A thermopile generates a typical voltage of up to
Antworten
  • 500mv
  • 600mv
  • 700mv
  • 800mv

Frage 17

Frage
Which of these two devices has a constant temperature to resistance ratio?
Antworten
  • RTD
  • Thermistor

Frage 18

Frage
The types of contacts used in thermostats are?
Antworten
  • Mercury
  • Spring activated, snap-action, exposed
  • Glass-enclosed, magnet and armature snap-action
  • All the above

Frage 19

Frage
In a heating thermostat the anticipator has what type of connection with the contacts?
Antworten
  • Series connection
  • Parallel connection
  • Combination connection
  • Compound connection

Frage 20

Frage
In a cooling thermostat the anticipator has what type of connection with the contacts?
Antworten
  • Series connection
  • Parallel connection
  • Combination connection
  • Compound connection

Frage 21

Frage
Where is the best location for a thermostat?
Antworten
  • On an inside wall
  • On an outside wall
  • Under the HVAC
  • Directly opposite the heat flow

Frage 22

Frage
The usual setting of a high limit switch for a furnace is?
Antworten
  • 70-80 degrees C
  • 80-100 degrees C
  • 90-130 degrees C
  • 80-120 degrees C

Frage 23

Frage
When not connected to the power supply, the position of the thermocouple relative to the pilot flame should be adjusted to read?
Antworten
  • Open circuit test of 26-32 mv
  • Closed circuit test of 26-32 mv
  • Open circuit test of 7.5-15 mv
  • Closed circuit test of 7.5-15 mv

Frage 24

Frage
What type of control switch resets when the temperature drops 11 degrees below the set point?
Antworten
  • High limit/ fan control switch
  • Thermostat actuator switch
  • High limit main gas valve switch
  • Summer switch

Frage 25

Frage
What device is represented by the words COMP in a legend?
Antworten
  • Contactor
  • Compressor motor
  • Condenser fan motor
  • Indoor fan motor

Frage 26

Frage
What type of thermostat is used for a basic heating system?
Antworten
  • Two wire
  • Three wire
  • Five wire
  • Seven wire

Frage 27

Frage
Which type of thermostat will have an on-off-auto switch?
Antworten
  • Two wire
  • Three wire
  • Five wire
  • Seven wire

Frage 28

Frage
Which type of thermostat is used for combination heating and cooling units?
Antworten
  • Two wire
  • Three wire
  • Five wire
  • Seven wire

Frage 29

Frage
Which type of thermostat is required for two stage heat and two stage cooling?
Antworten
  • Two wire
  • Three wire
  • Five wire
  • Seven wire

Frage 30

Frage
When do you connect RH and RC together in a five wire thermostat
Antworten
  • When one control transformer is used
  • When two or more control transformers are used
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Jahreszahlen
silvana_hof
Strafrecht - Definitionen
myJurazone
Wahrscheinlichkeit
barbara91
IKA-Theoriefragen Serie 19 (15 Fragen)
IKA ON ICT GmbH
Globalization
Laura Overhoff
Wie schreibe ich eine wissenschaftliche Arbeit
Antonia C
GPSY ALPS
Simon Wirsching
Methoden der Stratigraphie
Weltraumkatze Fanroth
GESKO A WERB WS 2018/19
Caroline Hannah
Vetie Histopatho 2012 und 2011
Ann-Kathrin Riedel
Tierseuchenbekämpfung 2014
Birte Schulz