3.9 Boiler procedures

Beschreibung

Quiz am 3.9 Boiler procedures, erstellt von TRAVIS CANNING am 29/01/2016.
TRAVIS CANNING
Quiz von TRAVIS CANNING, aktualisiert more than 1 year ago
TRAVIS CANNING
Erstellt von TRAVIS CANNING vor fast 9 Jahre
12
1

Zusammenfassung der Ressource

Frage 1

Frage
In order to avoid scale formation and corrosion in the _____, the make up water for the feedwater supply must be properly treated
Antworten
  • dearator
  • boiler
  • furnace
  • tank

Frage 2

Frage
When examining the waterside surfaces, the inspector looks for signs of corrosion, pitting and ________ of the metal.
Antworten
  • bulging
  • blistering
  • cracking
  • wearing

Frage 3

Frage
During the high-pressure flush, the blowdown valves should be disconnected, if possible, to prevent them from getting plugged with _________
Antworten
  • water
  • dirt
  • rust
  • scale

Frage 4

Frage
Moisture absorbing material should be placed on trays inside the drums to absorb moisture from the ________
Antworten
  • metal
  • tubes
  • air
  • fuel

Frage 5

Frage
Inert gas, such as nitrogen, is connected to the drum vent to maintain approximately ______ kpa, positive pressure.
Antworten
  • 100
  • 35
  • 325
  • 500

Frage 6

Frage
When the pressure in the boiler steam drum drops to ______kPa, the drum vents are to be opened to avoid the formation of a vacuum within the boiler.
Antworten
  • 170
  • 500
  • 35
  • 1000

Frage 7

Frage
Which of the following is not a common cause of furnace explosions
Antworten
  • failure to purge the furnace adequately before start-up
  • admission of fuel to main burner before pilot flame or other ignition source is established.
  • Loss of id fan
  • attempting to light one burner off other burners, in operation
  • incorrect amount of air supplied to the burner can resulting in incomplete combustion

Frage 8

Frage
The operator must be familiar with manual operation of the ______system, in case of a system failure
Antworten
  • generator
  • water
  • control
  • air

Frage 9

Frage
___________ storage is preferable for boilers that are out of service for an extended period of time or in locations where freezing temperatures.
Antworten
  • Dry
  • Short
  • Wet
  • Long

Frage 10

Frage
In order for the gauge glass to show the correct level, all connections to the gauge glass and the water column, must be ______ to ensure they are clear and free from obstructions.
Antworten
  • tight
  • purged
  • blowndown
  • unblocked
Zusammenfassung anzeigen Zusammenfassung ausblenden

ähnlicher Inhalt

Teil B, Kapitel 3, Entscheidungsgrundlagen bei der Wahl der Rechtsform
Stefan Kurtenbach
Onkologie Grundlagen
angelagiulia
10 Fragen aus der Abiturprüfung Geschichte
barbara91
IKA-Theoriefragen Serie 17 (15 Fragen)
IKA ON ICT GmbH
BM 13 - Allgemeine Didaktik
Isabell St
Deutsch Partizip Perfekt - unregelmäßige Verben
Claus Lenz
KORRE VO - Fragenkatalog überarbeitet
Jennifer Riegler
PR / WS17 18
publizistik - bakk ..
Vetie Tierseuchen 2019
Tropsi B