Questão 1
Questão
Order of basic steps of offensive IAP
Responda
-
1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Second line-backup first, 6) Ensure adequate water supply, 7) Assigned search team(s), 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
-
1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
-
1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Establish secondary Search, 10) Adjust plan and reassign, 11), Evaluate progress 12) Overhaul.
-
1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Assigned search team(s), 5) Coordinated Ventilation, 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
Questão 2
Questão
Order used to Scan area with TIC to ensure it is safe to enter.
Responda
-
1) Examine Floor, 2) Look up at the ceiling, 3) Scan walls from Right to Left 4) Look back
-
1) Examine Floor, 2) Look up at the ceiling, 3) Look back 4) Scan walls from Right to Left
-
1) Look up at the ceiling, 2) Examine Floor, 3) Scan walls from Right to Left 4) Look back
-
1) Check Temperature of Room 2) Look up at the ceiling, 3) Examine Floor, 4) Scan walls from Right to Left 5) Look back
Questão 3
Questão
Early identification and Fire command structure to a concealed space fire can save the structure quickly
Questão 4
Questão
Attacking a fire from the exterior before entering a structure is not desirable tactic and should never be used
Questão 5
Questão
When ventilation is being performed on a fire it should have limited exhaust points
Questão 6
Questão
The primary search should not begin until after the attack line is in place with water on the fire and ventilation has begun
Questão 7
Questão
All Clear is called by
Responda
-
As soon as anyone including neighbors and third party advises everyone is out.
-
Only from the primary search team
-
Only after the secondary search team
-
Can be done by first attack line or primary search team
Questão 8
Questão
When multiple injured victims are encountered
Responda
-
A transport coordinator should be established
-
A Medical Group should be established
-
A Triage group, Treatment group and transportation group supervisors should be established
Questão 9
Questão
The Radio term used to either remove the occupants or not are
Responda
-
Removing occupants, Defend in place
-
Evacuating the occupants, Defend in place
-
Evacuating the Occupants, Defending the Occupants
-
Removing occupants, Defending the Occupants
Questão 10
Questão
Rescue efforts should be extended in the following order:
Responda
-
1) Most severely threatened, 2) Largest number, 3) the remainder of the fire area 4) exposed area
-
1) Largest number, 2) Most severely threatened, 3) the remainder of the fire area 4) exposed area
-
1) Most severely threatened, 2) the remainder of the fire area, 3) Largest number 4) exposed area
Questão 11
Questão
Once utilities are secured it should be reported immediately via radio to command
Questão 12
Questão
You are allowed to pull the meter if you have been trained and the main disconnect is not at the meter
Questão 13
Questão
Defensive Attack IAP order
Responda
-
1) Take command, 2)Conduct recon, 3) 1st attack line to best offensive position, 4) Coordinated Ventilation, 5) Assigned search team(s), 6) Ensure adequate water supply, 7) Second line-backup first, 8) Consider RIT, 9) Evaluate progress, 10) Adjust plan and reassign, 11) Establish secondary Search, 12) Overhaul.
-
1) Take Command, 2) Write off property already destroyed, 3) Prioritize property left to be saved, 4) Attach lines should be outside of collapse zones, 5) Direct all necessary streams onto exposures, 6) if no exposures, keep personnel back use large streams,. 7) Provide an adequate water supply, 8) Evaluate actions 9) adjust plan and reassign as needed 10) Engage a secondary search where allowed.
-
1) Take Command, 2) Write off property already destroyed, 3) Engage a primary search where allowed 4)Prioritize property left to be saved, 5) Attach lines should be outside of collapse zones, 6) Direct all necessary streams onto exposures, 7) if no exposures, keep personnel back use large streams,. 8) Provide an adequate water supply, 9) Evaluate actions 10) adjust plan and reassign as needed, 11) Engage a secondary search where allowed
-
1) Take Command, 2) Write off property already destroyed, 3) Engage a primary search where allowed 4)Prioritize property left to be saved, 5) Attach lines should be outside of collapse zones, 6) Evaluate actions, 7) if no exposures, keep personnel back use large streams,. 8) Provide an adequate water supply, 9) Direct all necessary streams onto exposures 10) adjust plan and reassign as needed, 11) Engage a secondary search where allowed
Questão 14
Questão
Secondary search is a systematic search for savable victims.
Questão 15
Questão
Defensive operations where no continuous water supply is immediately available the first line will be directed towards knocking the fire down, with secondary lines taking care of the exposures
Questão 16
Questão
Aggressive interior attack operations directed toward knocking down the fire, coupled with coordinated ventilation will always eliminate serious safety concerns.
Questão 17
Questão
When laddering a building how many feet should be above the roof line
Questão 18
Questão
If a working fire is in progress command should have how many additional personnel.
Responda
-
Three Times
-
Two Times
-
Four times
Questão 19
Questão
If a ranking officers arrives on scene and wants to take command he can do so before getting a status update from present command
Questão 20
Questão
Status report to transfer command consists of
Responda
-
1) Fire location 2) Fire extent, 3) Present strategic goals 4) effectiveness of tactical efforts, 5) Deployment of companies operating & staging
-
1) Fire location 2) Resources needed, 3) Present strategic goals 4) effectiveness of tactical efforts, 5) Deployment of companies operating & staging
-
1) Fire location 2) Fire extent, 3) Present strategic goals, 4) Deployment of companies operating & staging 5) resources needed
Questão 21
Questão
level-1 staging involves
Responda
-
The first 3-4 engines report to scene all others stage short of scene
-
The first 2 engines report to scene 3rd engine stops 1/2 block away and all others stage short of scene
-
The first engines goes to the scene and the 2nd and 3rd engine stops 1/2 block away until further orders and all others stage short of scene
Questão 22
Questão
The initial company on a high rise fire will have
Responda
-
SCBAs, TIC, high-rise pack, forcible entry tools, extra bottles
-
SCBAs, TIC, high-rise pack, forcible entry tools, extra 50' of hose
-
SCBAs, TIC, high-rise pack, forcible entry tools
Questão 23
Questão
On mid rises when first responding unit uses elevator to respond to 2nd floor below reported fire. Upon exiting elevator they should return the elevator over to manual so it can return to the lobby without any personnel.
Questão 24
Questão
To report emergencies not related to lost, trapped or injured personnel you should use what terminology over the radio
Responda
-
May day repeating twice
-
Priority traffic
-
Red Alert
Questão 25
Questão
Fire personnel should maintain how many feet from the downed line shall be implemented
Responda
-
50-150
-
75-100
-
75-150
-
50-100
Questão 26
Questão
What Offensive evolution can be used by a first-in engine company into the structure
Responda
-
Attack team
-
Primary Search
-
ALL
Questão 27
Questão
What does FIT stand for