Zusammenfassung der Ressource
Frage 1
Frage
The lubrication oil system of a gas turbine must be checked for:
1. Metal particles
2. Water contamination
3. Dirt contamination
4. Leaks
Antworten
-
1,2,4
-
1,3,4
-
2,3,4
-
1,2,3
-
1,2,3,4
Frage 2
Frage
Aero-derivative gas turbines normally use _______ bearings:
Antworten
-
Journal
-
Radial tilt-pad
-
Shell
-
Antifriction
-
Air
Frage 3
Frage
Micro-turbines normally use ______ bearings:
Antworten
-
Journal
-
Radial tilt-pad
-
Shell
-
Antifriction
-
Air
Frage 4
Frage
Auxillary systems on gas turbines are needed to:
1. Provide fuel at the proper temperature and pressures
2. Clean and treat fuels
3. Provide hydraulic fluid for bearing lubrication
4. Inject steam to clean the ducts and housing
5. Provide anti-icing
Antworten
-
1,2,3
-
2,3,4
-
3,4,5
-
1,2,5
-
2,4,5
Frage 5
Frage
The exhaust of a gas turbine most commonly contains:
1. Nitrogen oxides
2. Sulphur dioxide
3. Particulate matter
4. Carbon monoxide
Frage 6
Frage
Gas turbine oil systems consist of these basic components:
1. An oil reservoir to ensue an adequate supply of oil
2. Filters to ensure the oil is clean
3. Pumps to provide pressure
4. Coolers to ensure oil temperatures are kept within operating limits
5. Protective, monitoring and control devices
Antworten
-
1,2,3
-
1,2,4
-
1,3,4,5
-
2,3,4
-
1,2,3,4,5
Frage 7
Frage
All piping, fittings and reservoir use _____ to prevent corrosion.
Antworten
-
Stainless steel
-
Brass
-
Aluminum
-
Carbon steel
-
Polycarbonate
Frage 8
Frage
Gas turbine lubricating oil systems provide the basic functions of:
1. Lubricating sliding surfaces in the bearings
2. Sealing out dirt and moisture
3. Cooling the bearings
4. Sealing the gas passages
Frage 9
Frage
Exhaust systems are required on Gas turbines to:
1. Allow the installation of silencers
2. Allow the installation of heat recovery equipment
3. Direct the flow to heat recovery systems
4. Minimize power losses
5. protect operators
Antworten
-
1,3,5
-
1,2,3
-
3,4,5
-
1,4,5
-
1,3,4
Frage 10
Frage
A mandatory auxillary in a gas turbine installation is a/an:
Antworten
-
Generator
-
Reheater
-
Starting motor
-
Air heater
-
Water pump