What are the requirements for the DICOM Purge feature in order to work?
Respuesta
Images need to be cleared form the local PIC folder.
Images need to be archived to a PACS
Images need to be cleared form the local PIC folder OR Images need to be archived to a PACS
Images need to be cleared form the local PIC folder AND Images need to be archived to a PACS
Pregunta 2
Pregunta
What is required to enable the QC in Eye Care PACS
Respuesta
1. HL7 orders must be supported and activated.
2. User need to belong to SymphonyWebAutors Group
1. HL7 must be supported and activated.
2. User need to belong to SymphonyWebQCUsers Group
1. HL7 orders must be supported and activated.
2. User need to belong to SymphonyWebQCUsers Group
Pregunta 3
Pregunta
What is needed to configure the OISDFC.INI for DICOM archive of the DCZ container files
Respuesta
SOP Class and Transfer Syntax
SOP Class and Study UID
Instance UID & Transfer Syntax
Instance UID & Study UID
Pregunta 4
Pregunta
What type of HL7 messages do we support?
Respuesta
ADT, ORU, MDM, QRY, ORM, QBP, ACK
ORM, ORU, ADT, QRY, MFN, ACK
BAR, ADT, ORU, MFN, ACK, QRY, QBP
Pregunta 5
Pregunta
Message Trigger Events for HL7.
What are the activities that should cause the Information System (IS) to initiate a message:
Respuesta
The IS interface sends an order message (ORM) to EyeStation, when an order is created,
updated, or cancelled. This message usually contains patient and physician information along with
requested observation details.
The IS interface sends an ADT message to EyeStation, whenever a patient's demographics are
updated, or a patient is merged, or to send a response to demographics query.
The IS interface sends an MFN message to EyeStation, whenever a physician information is
added/updated.
Pregunta 6
Pregunta
Message Trigger Events
The following activities cause the EyeStation to initiate a message:
The EyeStation sends an order result message (ORU) to IS, whenever an order is fulfilled.
● The EyeStation sends an MDM or ORU message to IS, when a digital report is created or updated.
● The EyeStation sends a query message (QRY) to IS, whenever patient validation and additional
demographic data is required.
● The EyeStation sends an ACK message (positive or negative acknowledgement) to IS, when an
ORM, ADT, or MFN message is received and processed.
Respuesta
True
False
Pregunta 7
Pregunta
HL7 Message Rule file. What is the meaning of the different types of brackets?
Respuesta
{ } Curly braces indicate that a segment can repeat
[ ] Square brackets indicate that a segment is optional
{ } Curly braces indicate that a segment is optional
[ ] Square brackets indicate that a segment can repeat
Pregunta 8
Pregunta
With SegDef file we define what segments we expect
- How many
- What order
- Which messages do we use to add/update or merge.
Respuesta
True
False
Pregunta 9
Pregunta
What are the HASP bits needed for a MECP server with 8 users, import form IOLMaster, Spectralis, Nidek Micro-Perimeter, Oculus Pentacam, RetCam
Respuesta
Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Montage enabled, Auto History, Auto Stabilizer, Perfect View , Net HASP, OCT, VFA, ULT, MO1, CTP
Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Review, Montage enabled, Auto History, Auto Stabilizer, Perfect View, Net HASP OCT, VFA, ULT, MO1, CTP
Winstation Version Number 11, SymphonyWeb enabled, Symphony Web Number of Licenses: 8, Montage enabled, Auto History, Auto Stabilizer, Perfect View OCT, VFA, ULT, MO1, CTP